2013
DOI: 10.1016/j.jmbbm.2012.11.015
|View full text |Cite
|
Sign up to set email alerts
|

An improved panoramic digital image correlation method for vascular strain analysis and material characterization

Abstract: The full potential of computational models of arterial wall mechanics has yet to be realized primarily because of a lack of data sufficient to quantify regional mechanical properties, especially in genetic, pharmacological, and surgical mouse models that can provide significant new information on the time course of adaptive or maladaptive changes as well as disease progression. The goal of this work is twofold: first, to present modifications to a recently developed panoramic – digital image correlation (p-DIC… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
49
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 50 publications
(50 citation statements)
references
References 18 publications
1
49
0
Order By: Relevance
“…Multiple views were obtained by mounting a single camera on a special rig that accurately positioned the camera along a given viewing direction (e.g. along a line c inclined to the desired stereo-angle with respect to the axis z of the conical mirror; figure 2) and then allowed a rotation over 360 • to collect the required set of polar-symmetrical stereo views [7]. In particular, the camera was mounted on a large custom dual-axis translational stage that was fixed on a kinematic mount (figure 2).…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Multiple views were obtained by mounting a single camera on a special rig that accurately positioned the camera along a given viewing direction (e.g. along a line c inclined to the desired stereo-angle with respect to the axis z of the conical mirror; figure 2) and then allowed a rotation over 360 • to collect the required set of polar-symmetrical stereo views [7]. In particular, the camera was mounted on a large custom dual-axis translational stage that was fixed on a kinematic mount (figure 2).…”
Section: Methodsmentioning
confidence: 99%
“…Each view was inclined relative to the opposite one at a stereo-angle 2θ of about 8 • . Note that this p-DIC stereo-angle increases with the sample size, going from 2θ < 2 • for mouse arteries having a diameter of approximately 1 mm [4][5][6][7] to 2θ = 8-12…”
Section: (C) Image and Data Processingmentioning
confidence: 98%
See 3 more Smart Citations