Abstract: High-resolution (HR) electrical mapping is an important clinical research tool for understanding normal and abnormal gastric electrophysiology. Analyzing velocities of gastric electrical activity in a reliable and accurate manner can provide additional valuable information for quantitatively and qualitatively comparing features across and within subjects, particularly during gastric dysrhythmias. In this study we compared three methods of estimating velocities from HR recordings to determine which method was t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
53
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 45 publications
(53 citation statements)
references
References 24 publications
0
53
0
Order By: Relevance
“…31 Velocity was calculated using a finite difference method with Gaussian-smoothing filter, and visualized using directional arrows on a color-gradient speed map. 32 In addition, velocity was secondarily averaged across regions of circumferential and longitudinal propagation, to investigate conduction anisotropy. 33 Amplitudes were calculated by applying a peak-to-trough detection algorithm.…”
Section: Methodsmentioning
confidence: 99%
“…31 Velocity was calculated using a finite difference method with Gaussian-smoothing filter, and visualized using directional arrows on a color-gradient speed map. 32 In addition, velocity was secondarily averaged across regions of circumferential and longitudinal propagation, to investigate conduction anisotropy. 33 Amplitudes were calculated by applying a peak-to-trough detection algorithm.…”
Section: Methodsmentioning
confidence: 99%
“…All data analysis was performed in the Gastrointestinal Electrical Mapping Suite (GEMS) software (v1.5) (Yassi, O'Grady et al 2012). Details of filtering (Paskaranandavadivel, O'Grady et al 2013), slow wave event and dysrhythmia detection, and data presentation methods (activation, amplitude and velocity mapping) were reported in detail a previous set of studies (O'Grady, Egbuji et al 2011; O'Grady, Angeli et al 2012; Paskaranandavadivel, O'Grady et al 2012). Unless otherwise mentioned, the data are reported in mean ± SEM.…”
Section: Methodsmentioning
confidence: 99%
“…The amplitude and velocity of each wavefront were also calculated using methods previously described [8], [14]. …”
Section: Methodsmentioning
confidence: 99%