1981
DOI: 10.1016/0009-8981(81)90404-6
|View full text |Cite
|
Sign up to set email alerts
|

An improved, highly sensitive method for the determination of serum iron using chromazurol B

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0

Year Published

1986
1986
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…This solution turns blue violet at pH 13 (595 nm). It is a highly sensitive colorimetric reagent for Fe(III) and is utilized for the determination of the iron content in blood serum at pH 4.4-5.5 in the presence of cetyltrimethylammonium bromide [33,34]. The dye has been utilized for spectrophotometric determination of protein (human serum albumin) using Chrom Azurol B-beryllium(II) complex by manual and flowinjection methods [35].…”
Section: Dynamic Sorption Of U(vi)mentioning
confidence: 99%
“…This solution turns blue violet at pH 13 (595 nm). It is a highly sensitive colorimetric reagent for Fe(III) and is utilized for the determination of the iron content in blood serum at pH 4.4-5.5 in the presence of cetyltrimethylammonium bromide [33,34]. The dye has been utilized for spectrophotometric determination of protein (human serum albumin) using Chrom Azurol B-beryllium(II) complex by manual and flowinjection methods [35].…”
Section: Dynamic Sorption Of U(vi)mentioning
confidence: 99%
“…The CRX Iron Kit is based on the use of chromazurol B, which creates a complex with Fe 3+ for the direct determination of the labile iron in a buffered acidic environment . No reduction step is needed before the interaction between sample and reagent.…”
Section: Discussionmentioning
confidence: 99%
“…In our methodology, for the quantification of zinc in serum, we employed a spectrophotometric determination method facilitated by an Elabscience Biotechnology Kit (Tokimoto et al, 2003), whereas iron concentrations were measured using a kit from QUÍMICA CLÍNICA APLICADA S.A. ( Tobacco et al, 1981) , employing a similar spectrophotometric approach. Vitamin D levels were assessed through the Cobas e 411 analyzer, which leverages electrochemiluminescence (ECL) technology for immunoassay analyses, another innovation from Roche Diagnostics Ltd. (Roach Diagnostic company, Forrenstrasse Rotkreuz, Switzerland).…”
Section: Methods For Determinationsmentioning
confidence: 99%