2021
DOI: 10.1016/j.powtec.2021.04.025
|View full text |Cite
|
Sign up to set email alerts
|

An improved high accuracy PTV algorithm for pebble flow

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 49 publications
0
4
0
Order By: Relevance
“…In Liu et al.’s work, the published three-point cocircle and the LP polygon algorithm were used for the amending method. This proved to be an effective method to improve the accuracy of particle tracking for the whole process of discharging Figure d,e shows the failed amending by the method of the three-point cocircle and the successful amending by the method of the L–P polygon.…”
Section: Programs For Experimental Data Processingmentioning
confidence: 94%
See 3 more Smart Citations
“…In Liu et al.’s work, the published three-point cocircle and the LP polygon algorithm were used for the amending method. This proved to be an effective method to improve the accuracy of particle tracking for the whole process of discharging Figure d,e shows the failed amending by the method of the three-point cocircle and the successful amending by the method of the L–P polygon.…”
Section: Programs For Experimental Data Processingmentioning
confidence: 94%
“…This proved to be an effective method to improve the accuracy of particle tracking for the whole process of discharging. 49 Figure 5d,e shows the failed amending by the method of the three-point cocircle and the successful amending by the method of the L−P polygon. Note that R p represents the radius of particles.…”
Section: Particlementioning
confidence: 99%
See 2 more Smart Citations
“…If the center of a particle in the second frame image is within the radius of a particle in the first frame image, they are considered one particle. Therefore, the inter-frame time shall be short enough so that the displacement of a particle in two successive frame images is not larger than the particle radius [40]. The allowable maximum particle velocity shall be 2 m•s −1 according to the frame rate of 2000 FPS and the particle radius of 1 mm, which is larger than the actual maximum particle velocity of about 0.7 m•s −1 in this experiment, so accurate matching can be guaranteed.…”
Section: Particle Tracking Velocimetrymentioning
confidence: 99%