2013
DOI: 10.1002/jsfa.6423
|View full text |Cite
|
Sign up to set email alerts
|

An immunochromatographic assay for rapid and direct detection of 3‐amino‐5‐morpholino‐2‐oxazolidone (AMOZ) in meat and feed samples

Abstract: The proposed ICA provides a feasible tool for simple, sensitive, rapid, convenient and semi-quantitative detection of AMOZ in meat and feed samples on site. To our knowledge, this is the first report of the ICA for direct detection of AMOZ.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
13
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 33 publications
1
13
0
Order By: Relevance
“…The quantitative LOD of 2-NP-AMOZ was 0.74 ng/mL, which corresponded to AMOZ at a concentration of 0.45 ng/mL after calculation by the following formula: concentration of AMOZ = (molecular weight of AMOZ/ molecular weight of 2-NP-AMOZ) × concentration of 2-NP-AMOZ. The use of QDs improved the sensitivity of immunostrip compared to the colloidal gold-based immunostrip, according to what observed for AMOZ detection by previously reported in the literature (Li et al, 2014).…”
Section: Characterization Of Qds and Qds-mab Conjugatessupporting
confidence: 81%
See 2 more Smart Citations
“…The quantitative LOD of 2-NP-AMOZ was 0.74 ng/mL, which corresponded to AMOZ at a concentration of 0.45 ng/mL after calculation by the following formula: concentration of AMOZ = (molecular weight of AMOZ/ molecular weight of 2-NP-AMOZ) × concentration of 2-NP-AMOZ. The use of QDs improved the sensitivity of immunostrip compared to the colloidal gold-based immunostrip, according to what observed for AMOZ detection by previously reported in the literature (Li et al, 2014).…”
Section: Characterization Of Qds and Qds-mab Conjugatessupporting
confidence: 81%
“…The synthesis of the AMOZ derivatives was performed as described previously with slight modification (Li et al, 2014). Briefly, 1.5 mmol of 4-carboxybenzaldehyle was dissolv in 5 mL dried methanol, followed by the addition of 1.0 mmol AMOZ.…”
Section: Preparation Of Amoz Derivatives and Immunogensmentioning
confidence: 99%
See 1 more Smart Citation
“…The extraction steps required generally depend upon the specificity and sensitivity of the antibody for the target in question and the matrix under analysis. Some published methods [18,19,23,26,45,55,56], especially for immunochromatographic and biosensor applications, use no sample derivatisation. In these cases the authors claim that antibody sensitivity and specificity for the underivatised nitrofuran metabolites is sufficient such that, when methods are calibrated with underivatised standards, detection can be achieved to meet the MRPL.…”
Section: Sample Preparationmentioning
confidence: 99%
“…The ICA detection was completed within 10 min. 24 Wang et al established multiplex ICA using gold nanoparticles for the rapid and simultaneous detection of four nitrofuran metabolites in sh samples. The multi-ICA detection was accomplished in less than 15 min by the naked eye.…”
mentioning
confidence: 99%