1999
DOI: 10.1046/j.1365-2044.1999.00892.x
|View full text |Cite
|
Sign up to set email alerts
|

An in vitro evaluation of flow from multihole epidural catheters during continuous infusion with four different infusion pumps

Abstract: SummaryWe have observed in vitro the distribution of flow from 10 identical multihole epidural catheters during continuous infusion with four different infusion pumps. The pumps chosen were the B Braun Perfusor Secura FT syringe driver and three volumetric infusion pumps utilising different pumping mechanisms (Dekra 3000 BL, Graseby 500 and CADD-Prizm). These pumps infused 0.9% saline through each catheter at 5 ml.h À1 , 15 ml.h À1 , 50 ml.h À1 and 99 ml.h À1 for 3 min. The number of holes through which flow o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
1

Year Published

2009
2009
2016
2016

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 12 publications
0
6
1
Order By: Relevance
“…Despite the differences between our study and studies of multi‐hole epidural catheters reported previously (McAtamney et al. ; Fegley et al. ), our finding of uneven distribution of flow are similar.…”
Section: Discussioncontrasting
confidence: 57%
See 2 more Smart Citations
“…Despite the differences between our study and studies of multi‐hole epidural catheters reported previously (McAtamney et al. ; Fegley et al. ), our finding of uneven distribution of flow are similar.…”
Section: Discussioncontrasting
confidence: 57%
“…Similar previous studies evaluated epidural catheters with a small number of holes, and at the relatively high injection rates that characterize intermittent bolus dosing (McAtamney et al. ; Fegley et al. ).…”
Section: Discussionmentioning
confidence: 67%
See 1 more Smart Citation
“…* 2011 American Society of Regional Anesthesia and Pain Medicine enhances these benefits 16,20,22Y26 Similarly, the benefits of intermittent bolus regimens may apply only to multiorifice catheters. 8,15,27 Flow from a multiorifice catheter has been shown to depend on the flow rate: below 80 mL/hr, multiorifice catheters function like single-orifice catheters. 15 Therefore, the present results may not be generalizable to infusion-only regimens:…”
Section: Discussionmentioning
confidence: 99%
“…8,15,27 In other words, to realize the benefits of the multiorifice design, flow rates greater than 100 mL/hr need to be deliveredVflow rates that can be delivered only with intermittent bolus regimens. Extrapolating from in vitro experiments, the regimen used in the present study likely resulted in tripleorifice flow during the manual primary local anesthetic bolus (9400 mL/hr), double-orifice flow during on-demand boluses (150 mL/hr), and single-orifice flow during the background infusion (2 mL/hr).…”
Section: Discussionmentioning
confidence: 99%