2008
DOI: 10.1016/j.jelechem.2008.02.017
|View full text |Cite
|
Sign up to set email alerts
|

An HMV mapping study of a pulsating jet system

Abstract: A new system for the generation of hydrodynamic modulated voltammetry (HMV) is presented. This system consists of an oscillating jet produced through the mechanical vibration of a large diaphragm. The structure of the cell is such that a relatively small vibration is transferred to a large fluid flow at the jet outlet. ) it can also be used to create a HMV system where a 'lock -in' approach is adopted to investigate the redox chemistry in question. This is demonstrated for the Fe(CN) 6 3-/4-redox system. Here … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
16
0

Year Published

2009
2009
2013
2013

Publication Types

Select...
3

Relationship

3
0

Authors

Journals

citations
Cited by 3 publications
(18 citation statements)
references
References 25 publications
(24 reference statements)
2
16
0
Order By: Relevance
“…However, in the course of previous investigations, mapping of the electrochemical response of the system identified some unusual characteristics [2]. First, the current pulses produced by this apparatus exhibited a strong 'ring' like relationship with the edge of the jet mouth [2]. Second, the size of the electrode surround (or support) also affected the mapping data, with a 'halo' effect detected.…”
Section: Introductionmentioning
confidence: 87%
See 4 more Smart Citations
“…However, in the course of previous investigations, mapping of the electrochemical response of the system identified some unusual characteristics [2]. First, the current pulses produced by this apparatus exhibited a strong 'ring' like relationship with the edge of the jet mouth [2]. Second, the size of the electrode surround (or support) also affected the mapping data, with a 'halo' effect detected.…”
Section: Introductionmentioning
confidence: 87%
“…Oscillation of the membrane was driven by a mechanical shaker (a Model V4, Signal Force, Data Physics Ltd) attached to the centre of a piston/membrane assembly (note although the piston assembly provided significantly improved HMV performance when compared to the membrane system, both will be used in the results discussed here). Figure 1 shows a schematic of a section of the pulsating jet apparatus imaged in the experiments reported here with particular reference to the region of direct interest where the imaging and electrochemical scanning experiments where concentrated [2]. Note variants of the complete apparatus can be found described previously in more detail [1][2][3].…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations