1992
DOI: 10.1109/61.141835
|View full text |Cite
|
Sign up to set email alerts
|

An expert system for high-voltage substations lightning performance estimation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
18
0
1

Year Published

1997
1997
2016
2016

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(19 citation statements)
references
References 6 publications
0
18
0
1
Order By: Relevance
“…The first event is represented with the mean value of the probability of the overvoltages occurrence exceeding the BIL of the transformer due to a strike somewhere on the analyzed span of the line. This value is calculated by means of the probabilistic method of limiting parameters and the procedure described in [4,7]. Substation configuration denotes the second parameters having influence (1) i=l where Pci is the probability of the i-th configuration.…”
Section: Statistical Methods For the Lightning Performance Estimationmentioning
confidence: 99%
See 2 more Smart Citations
“…The first event is represented with the mean value of the probability of the overvoltages occurrence exceeding the BIL of the transformer due to a strike somewhere on the analyzed span of the line. This value is calculated by means of the probabilistic method of limiting parameters and the procedure described in [4,7]. Substation configuration denotes the second parameters having influence (1) i=l where Pci is the probability of the i-th configuration.…”
Section: Statistical Methods For the Lightning Performance Estimationmentioning
confidence: 99%
“…The strokes to only first two spans are analyzed. The strokes to other spans v v vare not dangerous due to the travelling wave attenuation and distortion[4,6]. Similar equivalent circuits are formed for the other dispositions according toFig.…”
mentioning
confidence: 98%
See 1 more Smart Citation
“…Za statističku analizu atmosferskih prenapona razvijeno je više metoda, koje uvažavaju zakone raspodele amplitude i strmine struje groma. Za praktičnu primenu pogodna je metoda krive opasnih parametara groma, kod koje se rizik kvara određuje integraljenjem funkcije gustine raspodele amplitude i strmine struje groma u oblasti iznad krive opasnih parametara groma [13,1]. Druga često korišćena metoda za statističku analizu atmosferskih prenapona je Monte Karlo metoda, koja se primenjuje kada nisu egzaktno poznati svi ulazni parametri ali su poznate funkcije raspodela prema kojima se parametri menjaju, kao što je ovde slučaj.…”
Section: Rezultati Statističkog Pristupaunclassified
“…Although the impact of lightning overvoltages to the OHL has been considered since the first AC transmission line was placed in service, this subject has been discussed again in some recently published scientific papers. [1][2][3][4] The lightning performance of an OHL can be evaluated using a simple empirical formulae, 5,6 specialized software, [7][8][9][10] or by direct registration of OHL trip outs caused by lightning. 11,12 The simple empirical formulae 5,6 should be used for rough estimations of the OHL and substation lightning performances.…”
Section: Introductionmentioning
confidence: 99%