2007
DOI: 10.1016/j.compositesb.2006.09.004
|View full text |Cite
|
Sign up to set email alerts
|

An experimental study on the effect of environmental exposures and corrosion on RC columns with FRP composite jackets

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0
1

Year Published

2010
2010
2019
2019

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 52 publications
(17 citation statements)
references
References 9 publications
0
14
0
1
Order By: Relevance
“…As shown in Refs. [3][4][5], the resistance of the filament to corrosion is mainly dependant on the resin's corrosion resistance, and the corrosion crack propagation is also related to the resin toughness. The lack of complete understanding of the basic mechanisms of damage and degradation of the fiber is obvious.…”
Section: Introductionmentioning
confidence: 99%
“…As shown in Refs. [3][4][5], the resistance of the filament to corrosion is mainly dependant on the resin's corrosion resistance, and the corrosion crack propagation is also related to the resin toughness. The lack of complete understanding of the basic mechanisms of damage and degradation of the fiber is obvious.…”
Section: Introductionmentioning
confidence: 99%
“…recommended removing all contaminated concrete prior to repair and sealing areas of concrete most likely to be exposed [180]. Belarbi and Bae performed several tests on small-scale RC columns under ambient environmental conditions and accelerated corrosion conditions [181]. The corrosion tests showed that the FRP wrapped specimen can experience corrosion during the dry stage of wet/dry cycling because of entrapped moisture [181].…”
Section: Long-term Performance Of Frp Composite-retrofitted Structurementioning
confidence: 99%
“…Belarbi and Bae performed several tests on small-scale RC columns under ambient environmental conditions and accelerated corrosion conditions [181]. The corrosion tests showed that the FRP wrapped specimen can experience corrosion during the dry stage of wet/dry cycling because of entrapped moisture [181]. Other experimental studies showed that FRP wraps are successful in slowing the corrosion rate of internal steel reinforcement [182,183].…”
Section: Long-term Performance Of Frp Composite-retrofitted Structurementioning
confidence: 99%
“…Modulus of the FRP composite was observed not to be affected by any of the exposures. Bae (2004) and Belarbi and Bae (2007) studied the effects of various environmental conditions on the mechanical properties of reinforced concrete columns confined with FRP. Specimens were subjected to freeze-thaw, high temperature and high humidity cycles; ultraviolet (UV) radiation; and saline solution.…”
Section: Introductionmentioning
confidence: 99%