An Experimental Setup for Instrumental Analysis of Femoral Derotation Osteotomy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(12 citation statements)
references
References 0 publications
0
11
0
1
Order By: Relevance
“…The accessible bone surface between both k‐wires and the line of osteotomy were sampled with an EMT pointer device (FlexPointer E01 2002, fiagon GmbH, Berlin, Germany) for virtual reconstruction of local femur geometry, delivering the required context to calculate total derotation effect in the transversal plane. The bone shaft axis (rotational axis) is obtained using numerical optimization . Real time processing, analysis and documentation of the collected measurement data were carried out using previously developed research software interfacing with the tracking hardware (see Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The accessible bone surface between both k‐wires and the line of osteotomy were sampled with an EMT pointer device (FlexPointer E01 2002, fiagon GmbH, Berlin, Germany) for virtual reconstruction of local femur geometry, delivering the required context to calculate total derotation effect in the transversal plane. The bone shaft axis (rotational axis) is obtained using numerical optimization . Real time processing, analysis and documentation of the collected measurement data were carried out using previously developed research software interfacing with the tracking hardware (see Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The intra‐operative derotation angle was controlled by the Electromagnitc tracking system operated by a technician. The system setup included a field generator (Aurora v.2, Northern Digital, Waterloo, Canada) in combination with EMT sensors embedded in a clamp shell (PointerShell E01 2902, fiagon GmbH, Berlin, Germany) . The sensors were attached to the same conventional k‐wires used for optical goniometric control as described in detail above.…”
Section: Methodsmentioning
confidence: 99%
“…Virtual reconstruction of local femur geometry and the osteotomy site was accomplished through sampling of the bone surface between both K‐wires and the line of osteotomy with an EMT pointer device (FlexPointer E01 2002, fiagon GmbH, Berlin, Germany) delivering the required context to calculate total derotation effect in the transversal plane. The bone shaft axis (rotational axis) is obtained using numerical optimization . Real time processing, analysis, and documentation of the collected measurement data was carried out using previously developed research software interfacing with the tracking hardware (Also see supplement Figs.…”