Abstract:The most important design parameters of a moisture separator to optimize the efficiency of a nuclear power plant are the moisture carry over and pressure drop. An air-water test facility was constructed to evaluate the design parameters for various types of conventional moisture separators in Korea. In this study, a half scale of swirl-vane separator was designed, and test conditions were defined based on the scaling law to cover a wide range of operating conditions. The moisture carry over was measured using … Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.