Advances in X-Ray Analysis 1993
DOI: 10.1007/978-1-4615-2972-9_76
|View full text |Cite
|
Sign up to set email alerts
|

An Experimental Examination of Error Functions for Bragg-Brentano Powder Diffractometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

1993
1993
2012
2012

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 16 publications
0
2
0
Order By: Relevance
“…But as is demonstrated below, the refined value may not represent the true aberration. Because no calibration material exists for the entire scanning range of a Bragg-Brentano diffractometer (Klug and Alexander, 1972) and no development of a single function for the elimination of errors has yet been achieved (King and Payzant, 1993), the use of an internal standard will not guarantee the accuracy of the lattice parameters refined. It has been pointed out recently (Toraya and Ochiai, 1994) that the whole powder pattern fitting technique with the absence of a structural model may be more suitable to lattice parameter refinement than the Rietveld analysis which imposes a structural constraint on each phase including the internal standard.…”
Section: Lattice Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…But as is demonstrated below, the refined value may not represent the true aberration. Because no calibration material exists for the entire scanning range of a Bragg-Brentano diffractometer (Klug and Alexander, 1972) and no development of a single function for the elimination of errors has yet been achieved (King and Payzant, 1993), the use of an internal standard will not guarantee the accuracy of the lattice parameters refined. It has been pointed out recently (Toraya and Ochiai, 1994) that the whole powder pattern fitting technique with the absence of a structural model may be more suitable to lattice parameter refinement than the Rietveld analysis which imposes a structural constraint on each phase including the internal standard.…”
Section: Lattice Parametersmentioning
confidence: 99%
“…On the other hand, a Rietveld code not equipped with the cos 2 0 function, but only a sample displacement error function and goniometer-zero correction, will yield a value which deviates at least +0.0005 A from the true value. In situations where no singular error function will suffice dominant errors have to be deconvoluted (King and Payzant, 1993). Al powder 5 /xm in size mounted with DUCO cement into a 1.5 mm-deep sample holder cavity and surface polished in ethanol produced a cos 6 cot 6 plot which is shown in Figure 3.…”
Section: Lattice Parametersmentioning
confidence: 99%