An experimental and mathematical study of efforts of a novel photovoltaic-Trombe wall on a test room

Abstract: SUMMARYA novel photovoltaic-Trombe wall (PV-TW) is proposed and investigated experimentally and theoretically in this paper. The PV-TW was installed at the south-facing external wall of an environmental chamber that carried two identical test rooms. Both of the test rooms have a double window of the same size. One test room was installed with the PV-TW (known as the PV-TW room), and the other without PV-TW (known as the reference room). The influence of the PV-TW on the thermal environment of the test room was… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 19 publications
(16 reference statements)
0
4
0
Order By: Relevance
“…They found that the mean indoor air temperature in the room with PV-G Trombe wall was higher than that in the reference room without PV-G wall with ranges from 5-7 °C. Ji et al [39][40] [41][42] studied the effects of thermal insulation and shading curtain on the performance of PV-G systems in Hefei, China through simulations. They found that with the application of thermal insulation to PV-G, the electrical efficiency was decreased by 2% while the indoor air temperature was increased by 2.4 °C in winter and decreased by 2.5 °C in summer.…”
Section: Discussionmentioning
confidence: 99%
“…They found that the mean indoor air temperature in the room with PV-G Trombe wall was higher than that in the reference room without PV-G wall with ranges from 5-7 °C. Ji et al [39][40] [41][42] studied the effects of thermal insulation and shading curtain on the performance of PV-G systems in Hefei, China through simulations. They found that with the application of thermal insulation to PV-G, the electrical efficiency was decreased by 2% while the indoor air temperature was increased by 2.4 °C in winter and decreased by 2.5 °C in summer.…”
Section: Discussionmentioning
confidence: 99%
“…The energy efficiency of BIP−/TE system was 1.26 higher than a massive wall. An environmental chamber with a roof‐top was integrated with PV‐TW to investigate the overall system performance in Hefei, China . Generating electricity and improving the room thermal condition were confirmed experimentally and theoretically.…”
Section: Applications Of Pv‐trombe Wall In Buildingmentioning
confidence: 92%
“…Lρ air c air ∂T air ∂t = h air (T pv − T air ) + h air (T g − T air ) − Lρ air V air c air ∂T air ∂y (12) where ρ air , c air , and T air were the density, heat capacity and temperature of the air channel, respectively. V air was the air velocity in the channel, and defined as [33,35]:…”
Section: Air Channelmentioning
confidence: 99%