Abstract:A beam-column connection of cold-formed steel section was arranged as an isolated joint. An experimental testing has been done on the model specimen until the model reached its failure mode. The behaviour of the cold-formed bolted connection in the matter of its strength and stiffness of the steel connection was studied. In this study, gusset-plate and bolted angle flange cleat connection were used in which it can stiffen the cold-formed beam-column connection. Moment-rotation curves were generated from the te… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.