2018
DOI: 10.1016/j.measurement.2017.11.030
|View full text |Cite
|
Sign up to set email alerts
|

An evaluation of the anticorrosion effect of ethylene glycol for AA7075-T6 alloy in 3.5% NaCl solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0
1

Year Published

2019
2019
2022
2022

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 21 publications
(4 citation statements)
references
References 35 publications
(60 reference statements)
0
3
0
1
Order By: Relevance
“…The relationship between the C dl value and the thickness of the adsorbed layer on the Al surface is given by the following equation [ 56 , 57 ]: where is the thickness of the adsorbed layer on the metal surfaces, represents the permittivity of air, expresses the constant of local dielectric, and A is the surface area of the metal electrodes.…”
Section: Resultsmentioning
confidence: 99%
“…The relationship between the C dl value and the thickness of the adsorbed layer on the Al surface is given by the following equation [ 56 , 57 ]: where is the thickness of the adsorbed layer on the metal surfaces, represents the permittivity of air, expresses the constant of local dielectric, and A is the surface area of the metal electrodes.…”
Section: Resultsmentioning
confidence: 99%
“…Each sample of the experiment was carried out three times to ascertain reproducibility. Current density ( j corr ) as well as polarization potential ( E corr ), were extracted from the tafel plots and the percentage inhibition performance efficiency (IPE %) was computed using Equations 1 and 2 and the surface courage (Θ) was also computed from the values achieved from the tafel plot using Equations 1 and 2 corrosion results for the fabricated composite and the parent metal has been extracted while the open circuit potential and the tafel polarization curve was plotted from the extracted data , Table , Figure . trueθ1.69998pt=1.69998pt1-4ptjcorrj0corr trueIPE4pt%1.69998pt=1.69998pt1-4ptjcorrj0corr4pt×100 …”
Section: Resultsmentioning
confidence: 99%
“…Analysis of the polarization curves was carried out using the Gamry Echem Analyst program. For dynamic-EIS, the sampling frequency was 12.8 kHz, the perturbation signal was in the range of 4.5 kHz–300 mHz, and the measurement was carried out for 30 h. Detailed information on how the National Instruments Measurement Ltd. PCI-4461digital analogue card works can be found in our previous publications. Each experiment was repeated three times, and the average values are presented in this work.…”
Section: Methodsmentioning
confidence: 99%