2022
DOI: 10.1039/d2lc00183g
|View full text |Cite
|
Sign up to set email alerts
|

An epidermal wearable microfluidic patch for simultaneous sampling, storage, and analysis of biofluids with counterion monitoring

Abstract: Simultaneous access to the different biofluids enables an accurate analysis of multiple analytes, leading to a precision diagnosis and medication. Additionally, establishing a relationship between various markers at different biofluids...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 21 publications
(21 citation statements)
references
References 64 publications
0
21
0
Order By: Relevance
“…71 The ISF is more similar in composition to blood than sweat, hence higher analyte concentrations for biosensing. 72,73 Aside from in situ ISF sensing, 16,74 recent works reported collecting the ISF, 19,75 for downstream analysis such as transcriptomics, 72 proteomics, 76 and metabolomics. 72 This is due to ISF sampling via MN avoiding patient discomfort as compared to conventional blood sampling via hypothermic needle/finger prick.…”
Section: Resultsmentioning
confidence: 99%
“…71 The ISF is more similar in composition to blood than sweat, hence higher analyte concentrations for biosensing. 72,73 Aside from in situ ISF sensing, 16,74 recent works reported collecting the ISF, 19,75 for downstream analysis such as transcriptomics, 72 proteomics, 76 and metabolomics. 72 This is due to ISF sampling via MN avoiding patient discomfort as compared to conventional blood sampling via hypothermic needle/finger prick.…”
Section: Resultsmentioning
confidence: 99%
“…[ 84 ] Attaching a collection chamber at the end of the electrode may allow the collection and storage of a small volume of ISF. [ 85 ] Iontophoretic procedures are very limited by the molecule's charge due to its basic principle and the fact that skin itself has a negative net charge, making it selectively permeable for mostly cationic species. It works with small biomolecule extraction, but the instruments are bulky, and the interpretation of the results requires frequent calibration.…”
Section: Current Methods To Sample Interstitial and Other Tissue Fluidsmentioning
confidence: 99%
“…Microchannels parallel to the skin are connected to the sweat glands through vertical channels. [ 57 ] In the process of perspiration, sweat is concentrated in the vertical channels through the capillary force. After reaching a certain amount, the sweat flows through the microchannels under the action of the siphon effect and reaches the analysis area.…”
Section: Sweat Collection Methodsmentioning
confidence: 99%