2007
DOI: 10.1016/j.jhazmat.2006.09.085
|View full text |Cite
|
Sign up to set email alerts
|

An empirical model for parameters affecting energy consumption in boron removal from boron-containing wastewaters by electrocoagulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
22
0
4

Year Published

2010
2010
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(27 citation statements)
references
References 12 publications
(10 reference statements)
1
22
0
4
Order By: Relevance
“…So, when the conductivity increases, ability to carry electricity is also increased and low energy needed. That can explain the relation between pH and energy consumption [14]. The energy consumptions were 42, 52, 49 and 125 kWh/m 3 at pH of 3, 5, 7, and 9, respectively after 60 minutes EC operation.…”
Section: A Effect Of Initial Phmentioning
confidence: 72%
“…So, when the conductivity increases, ability to carry electricity is also increased and low energy needed. That can explain the relation between pH and energy consumption [14]. The energy consumptions were 42, 52, 49 and 125 kWh/m 3 at pH of 3, 5, 7, and 9, respectively after 60 minutes EC operation.…”
Section: A Effect Of Initial Phmentioning
confidence: 72%
“…The decrease in the pH of solution may increase conductivity of the solution. Therefore, when the conductivity increases, ability to carry electricity is also increased and low energy needed [10]. Therefore subsequent experiments were performed at pH 2 because of lower energy consumption.…”
Section: A Effect Of Initial Phmentioning
confidence: 99%
“…La razón podría ser que al aumentar la temperatura aumenta la movilidad y las colisiones de los iones. Además, aumentando la temperatura se facilita la generación del radical oxhidrilo debido al aumento de la transferencia de masa de las diversas especies con la temperatura, y esto conduce a un incremento de la reacción de los radicales con el agente contaminante [119,120].…”
Section: "Tratamiento De Disoluciones Que Contienen Cromo Hexavalenteunclassified
“…Usando electrodos de hierro para el tratamiento de aguas residuales, se ha comprobado que conforme aumenta la temperatura de 20 ºC a 30 ºC, aumenta la conductividad, reduciéndose así el consumo de energía. Sin embargo, cuando la temperatura sobrepasa los 37 ºC, la eficacia de eliminación disminuye, debido a la formación de flóculos inadecuados o a un aumento en la solubilidad de los precipitados que hace que la eficacia de eliminación disminuya [115,[119][120][121][122].…”
Section: "Tratamiento De Disoluciones Que Contienen Cromo Hexavalenteunclassified
See 1 more Smart Citation