2014 IEEE PES General Meeting | Conference &Amp; Exposition 2014
DOI: 10.1109/pesgm.2014.6938824
|View full text |Cite
|
Sign up to set email alerts
|

An empirical investigation of V-I trajectory based load signatures for non-intrusive load monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0
1

Year Published

2014
2014
2021
2021

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 0 publications
0
6
0
1
Order By: Relevance
“…A voltage-current ( -) trajectory was used as the load signature in [6] which has shown good performance in distinguishing between loads with similar patterns. A deeper vision of the -trajectory for load identification was introduced in [7], which improved the precision of predictions by 10% as compared to [6]. The features used in [7] include -, total harmonic distortion, and V-I wave-shape.…”
Section: Related Literaturementioning
confidence: 99%
See 2 more Smart Citations
“…A voltage-current ( -) trajectory was used as the load signature in [6] which has shown good performance in distinguishing between loads with similar patterns. A deeper vision of the -trajectory for load identification was introduced in [7], which improved the precision of predictions by 10% as compared to [6]. The features used in [7] include -, total harmonic distortion, and V-I wave-shape.…”
Section: Related Literaturementioning
confidence: 99%
“…A deeper vision of the -trajectory for load identification was introduced in [7], which improved the precision of predictions by 10% as compared to [6]. The features used in [7] include -, total harmonic distortion, and V-I wave-shape. Four learning algorithms were also used in [7], including artificial neural network (ANN), ANN coupled with an evolutionary algorithm, support vector machine (SVM), and Adaptive Boost.…”
Section: Related Literaturementioning
confidence: 99%
See 1 more Smart Citation
“…However, due to the latency and quick response requirements of this system we considered using a load disaggregation [6] and forecasting [8]. The data that was collected was passed to the PCAT.…”
Section: Salemmentioning
confidence: 99%
“…The main drawback of CH based load feature is that some household appliances consisting of linear and largely resistive elements result in low harmonic content of the load current, and thus requires great effort for load identification. Appliance LSs based on V-I trajectory is broadly discussed in [11], [12]. Both load current and voltage information can be captured in the V-I curvature.…”
Section: Introductionmentioning
confidence: 99%