1995
DOI: 10.1016/0022-0728(95)04199-x
|View full text |Cite
|
Sign up to set email alerts
|

An electroreflectance study of novel hemin-imidazole complexes at a pyrolytic graphite electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
18
0

Year Published

1998
1998
2011
2011

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(20 citation statements)
references
References 19 publications
2
18
0
Order By: Relevance
“…This is only about 40 mV higher than that obtained with a hemin-modified basal plane PG [34,53], glassy carbon [33], or PG electrode [54]. In addition, it is about 20 mV more positive than the formal potential of hemin adsorbed on an edge plane PG electrode [55]. Our result indicates that (a) the formal potential of hemin depends only slightly on the characteristics of the electrode surface and (b) the small positive shift of the potential observed may be attributed to an improved reversibility of electron transfer processes on the MWNTs [56].…”
Section: Immobilization Of Hemin At the Surface Of Mwntsmentioning
confidence: 62%
“…This is only about 40 mV higher than that obtained with a hemin-modified basal plane PG [34,53], glassy carbon [33], or PG electrode [54]. In addition, it is about 20 mV more positive than the formal potential of hemin adsorbed on an edge plane PG electrode [55]. Our result indicates that (a) the formal potential of hemin depends only slightly on the characteristics of the electrode surface and (b) the small positive shift of the potential observed may be attributed to an improved reversibility of electron transfer processes on the MWNTs [56].…”
Section: Immobilization Of Hemin At the Surface Of Mwntsmentioning
confidence: 62%
“…Atomic force microscopic (AFM) images were taken out using a Nanoscope III MultiMode SPM. [37,38]. In comparison, the UV-visible spectrum of CCG does not show any absorption band in the wavelength range of 300-800 nm.…”
Section: Instrumentationmentioning
confidence: 84%
“…2. The spectral curves are quite similar to the curves for hemin directly adsorbed on graphite electrodes [11,[14][15][16]. However, in light of the amount of electroactive species and the single-component signal feature, we look at hemin in the bulk film near the electrode but not only the adsorbed species.…”
Section: Fig 3 See Page 15mentioning
confidence: 73%
“…2: two negative-going ER band peaks at 439 and 544 nm and two positive-going peaks at 476 and 608 nm were observed. The spectral curve shape was independent of the modulation frequency (8,14, and 84 Hz).…”
Section: Fig 5 See Page 17mentioning
confidence: 94%
See 1 more Smart Citation