2017
DOI: 10.1016/j.snb.2017.05.058
|View full text |Cite
|
Sign up to set email alerts
|

An electrochemical sensor for the determination of Cu(II) using a modified electrode with ferrocenyl crown ether compound by square wave anodic stripping voltammetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
7
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 39 publications
(8 citation statements)
references
References 33 publications
1
7
0
Order By: Relevance
“…The incubated electrodes were used for the determination of Cu ions using DPV technique. The optimum pH value was determined to be 5.00 from this study and this result is supported by some studies [38][39][40][41][42]. At higher pH values, Cu ions cannot be detected due to the precipitation formation as hydroxide.…”
Section: Detection Of Cu(ii) On Modified Hmpd/gc Electrode By Differesupporting
confidence: 81%
“…The incubated electrodes were used for the determination of Cu ions using DPV technique. The optimum pH value was determined to be 5.00 from this study and this result is supported by some studies [38][39][40][41][42]. At higher pH values, Cu ions cannot be detected due to the precipitation formation as hydroxide.…”
Section: Detection Of Cu(ii) On Modified Hmpd/gc Electrode By Differesupporting
confidence: 81%
“…Carbon paste is often mixed with modifier to form a mixture (bulk modified), or coated with a modifier on the surface of working electrode (surface modified) (Wang, 2001;Raoof, et al, 2011). Some commonly used modifiers include crown ether (Flores et al, 2017), hematite (Wang et al, 2019), and ferrocene (Gonzalez et al, 2009;Raoof et al, 2011;Wu et al, 2010 ). Raoof et al (2011) modified carbon paste electrodes using ferrocene and obtained an optimum ferrocene composition of 0.6% with a linear concentration range of 0.03-2400 μM and a detection limit of 0.0096 μmol/L.…”
Section: Introductionmentioning
confidence: 99%
“…Conventional detection methods such as highperformance liquid chromatography (HPLC) are limited by high-cost equipment and sophisticated procedures, and cannot achieve in-situ measurements of heavy metal ions in complicated water bodies [2][3][4]. The portability of the device and in-situ measurement capability allows anodic stripping voltammetry to achieve rapid detection of heavy metal ions in water, and so it can be employed in online monitoring and pre-alerts of heavy metal ions in complicated water bodies [5,6]. As a core component for stripping analysis, glassy-carbon electrodes are limited by insufficient precision and detection limits for the simultaneous detection of different ions.…”
Section: Introductionmentioning
confidence: 99%