2016
DOI: 10.1016/j.snb.2015.09.055
|View full text |Cite
|
Sign up to set email alerts
|

An electrochemical immunosensor for adiponectin using reduced graphene oxide–carboxymethylcellulose hybrid as electrode scaffold

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(8 citation statements)
references
References 19 publications
0
7
1
Order By: Relevance
“…As can be seen in Table2, Arenas and co-workers developed an electrochemical immunosensor for adiponectin using reduced graphene oxide−carboxylmethylcellulose hybrids as electrode scaffolds. The LOD value is higher than the proposed GPbased immunosensor 43. Moreover, the modification processes take a little longer time compared to our study.…”
contrasting
confidence: 55%
“…As can be seen in Table2, Arenas and co-workers developed an electrochemical immunosensor for adiponectin using reduced graphene oxide−carboxylmethylcellulose hybrids as electrode scaffolds. The LOD value is higher than the proposed GPbased immunosensor 43. Moreover, the modification processes take a little longer time compared to our study.…”
contrasting
confidence: 55%
“…The increase of current was proportional to the HIV-p24 concentration between 0.5 pg mL −1 and 8.5 ng mL −1 , with a LoD of 0.15 pg mL −1 . At last, Arenas, Sánchez-Tirado et al [ 101 ] presented the detection of adiponectin (APN), an hormone involved in glucose and lipid metabolism with a central role in the regulation of insulinoresistance, with a sandwich-type assay involving a metal complexes-based polymer (Mix & Go™) for immobilization of the anti-APN capture antibody, and HRP-anti-APN as signaling antibody ( Figure 17 C). Using amperometry at −200 mV and the H 2 O 2 /HQ redox system in solution, they obtained a linear calibration within 0.5–10.0 μg mL −1 ; the LoD was 60 ng mL −1 .…”
Section: Discussionmentioning
confidence: 99%
“…Reprinted from [ 99 ], Copyright 2013, with permission from Elsevier; ( B ) Typical DPVs corresponding to MMP-2 concentrations from a to j (0, 0.0005, 0.005, 0.02, 0.05, 0.25, 1.0, 5.0, 10.0 and 50.0 ng mL −1 ) in PBS + 4 mM H 2 O 2 , and corresponding calibration curve; ( C ) The different steps involved in the construction of the adiponectin (APN) immunosensor using a metallocomplex polymer (CMC) and RGO on a screen-printed carbon electrode; ( D ) Corresponding calibration plot. Reprinted from [ 101 ], Copyright 2016, with permission from Elsevier.…”
Section: Figurementioning
confidence: 99%
“…Arenas et al [ 30 ] reported a sandwich-type immunosensor for the determination of APN by immobilizing the CAb at CMC–rGO/SPCEs in a stable and oriented way through the metal complexes-based polymer Mix&Go TM . In addition, Btn-DAb + Strep-HRP and amperometry in the presence of H 2 O 2 /HQ were used, achieving an LOD of 61 ng mL −1 .…”
Section: Bioelectroanalytical Methods For the Determination Of Infmentioning
confidence: 99%