2018
DOI: 10.1016/j.measurement.2017.11.006
|View full text |Cite
|
Sign up to set email alerts
|

An efficient data compression and encryption technique for PPG signal

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(9 citation statements)
references
References 44 publications
0
9
0
Order By: Relevance
“…where µ x denotes the mean of the original PPG signal [80]. This is also referred to as "percentage root mean squared difference (PRD)" [80], [82], [87]. The PRDN (PRD) is most widely used for assessing the quality of a decompressed signal or measuring distortion between the original and decompressed signal [80], [82], [87], [85].…”
Section: Existing Objective Distortion Measures For Assessing Decompressed Ppg Qualitymentioning
confidence: 99%
See 2 more Smart Citations
“…where µ x denotes the mean of the original PPG signal [80]. This is also referred to as "percentage root mean squared difference (PRD)" [80], [82], [87]. The PRDN (PRD) is most widely used for assessing the quality of a decompressed signal or measuring distortion between the original and decompressed signal [80], [82], [87], [85].…”
Section: Existing Objective Distortion Measures For Assessing Decompressed Ppg Qualitymentioning
confidence: 99%
“…This is also referred to as "percentage root mean squared difference (PRD)" [80], [82], [87]. The PRDN (PRD) is most widely used for assessing the quality of a decompressed signal or measuring distortion between the original and decompressed signal [80], [82], [87], [85]. In [83], quality control mechanism was implemented by using two objective quality criteria: the PRD to check the global reconstruction quality and maximum absolute error to measure local distortion in the PPG signal.…”
Section: Existing Objective Distortion Measures For Assessing Decompressed Ppg Qualitymentioning
confidence: 99%
See 1 more Smart Citation
“…The PPG signal is widely used in clinical settings to monitor physiological parameters related to the cardiorespiratory system [ 21 ]. It is complex.…”
Section: Introductionmentioning
confidence: 99%
“…There is a tradeoff between compression of a signal (compression ratio) and minimizing information loss [ 14 ]. Data compression has been explored for biomedical signals previously, but the evaluation of these methods has been limited to one type of sensor, including either electrocardiogram (ECG) [ 14 , 15 , 16 , 17 ], photoplethysmography (PPG) [ 18 , 19 , 20 ], accelerometry [ 21 , 22 ], and electrodermal activity (EDA) [ 23 ]. Data compression methods can be divided into two groups: Lossless compression and lossy compression.…”
Section: Introductionmentioning
confidence: 99%