An Effective Switching Algorithm for Single Phase Matrix Converter in Induction Heating Applications

Abstract: Prevalent converters for induction heating (IH) applications employ two-stage conversion for generating high-frequency magnetic field, namely, AC to DC and then DC to high-frequency AC (HFAC). This research embarks upon a direct conversion of utility AC to high frequency AC with the design of a single-phase matrix converter (SPMC) as a resonant converter using a modified switching technique for IH application. The efficacy of the proposed approach is validated through different attributes such as unity power f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
36
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(39 citation statements)
references
References 33 publications
0
36
0
Order By: Relevance
“…Therefore, the total number of switching combinations is 215 = 32768. However, the number of combinations reduces considerably because of the specific constraints listed below [12]. The constraints are:…”
Section: Matrix Converter Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, the total number of switching combinations is 215 = 32768. However, the number of combinations reduces considerably because of the specific constraints listed below [12]. The constraints are:…”
Section: Matrix Converter Modelmentioning
confidence: 99%
“…For this purpose, a secondary parameter p, as expressed in (12), is included in the cost function g to regulate the switching [23]. Secondary parameter p is defined as "the total sum of the change in the switching states of all individual switches of the matrix converter."…”
Section: Switching Frequency Regulationmentioning
confidence: 99%
“…According to (1) and (5), the inductances of the primary and frustum coils are fully compensated by their capacitances. Thus, the impedances Z p and Z f can be regarded as the pure resistances R p and R f , respectively:…”
Section: Proposed Induction Heating Systemmentioning
confidence: 99%
“…The selective operating frequency technique was developed for all-metal domestic induction heating [4]. Meanwhile, the effective six phase matrix converter was designed for induction heating with characteristics of zero voltage switching [5].…”
Section: Introductionmentioning
confidence: 99%
“…The conventional topology used for this excitation power supplies are mainly Buck DC chopper converter, H bridge DC chopper topology, multi pulse rectifier and so on [1][2][3][4]. However, conventional ion accelerator magnet excitation power supplies have some disadvantages.…”
Section: Introductionmentioning