2014
DOI: 10.3390/en7085129
|View full text |Cite
|
Sign up to set email alerts
|

An Economic and Environmental Assessment Model for Selecting the Optimal Implementation Strategy of Fuel Cell Systems—A Focus on Building Energy Policy

Abstract: Considerable effort is being made to reduce the primary energy consumption in buildings. As part of this effort, fuel cell systems are attracting attention as a new/renewable energy systems for several reasons: (i) distributed generation system; (ii) combined heat and power system; and (iii) availability of various sources of hydrogen in the future. Therefore, this study aimed to develop an economic and environmental assessment model for selecting the optimal implementation strategy of the fuel cell system, fo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 18 publications
(12 citation statements)
references
References 60 publications
0
12
0
Order By: Relevance
“…There are some studies about coal-fired boilers [7][8][9][10]. Figure 1 shows a schematic of a coal-fired oxy-fuel boiler [11], in which oxygen is first separated from the air and then mixed with a stream of recycled flue gases from the boiler.…”
Section: Oxygen Combustion In the Coal-fired Boilermentioning
confidence: 99%
“…There are some studies about coal-fired boilers [7][8][9][10]. Figure 1 shows a schematic of a coal-fired oxy-fuel boiler [11], in which oxygen is first separated from the air and then mixed with a stream of recycled flue gases from the boiler.…”
Section: Oxygen Combustion In the Coal-fired Boilermentioning
confidence: 99%
“…Possible alternatives of FC system can be established as follows [61]: (i) the target production of the heating and cooling energy with constraints (i.e., budget, area, size) is established through the application of the FC system; (ii) the scenarios of the FC system are established by considering the HVAC zone where the FC system is to be installed; and (iii) the energy production of the FC system is calculated by conducting energy simulation (the software program "RETScreen" and "Self-production program" based on the scenarios.…”
Section: Making Possible Alternatives Of Fc Systemmentioning
confidence: 99%
“…In this study, the analysis period was set by considering the service life of the NRE system [61][62][63][64][65].…”
Section: Step 4: Selecting Optimal System Through Life Cycle Cost Andmentioning
confidence: 99%
“…Lee et al (2015) determined the environmental impact associated with a solid-oxide fuel cell. Kim et al (2014) developed an economic and environmental assessment model for selecting the optimal implementation strategy of the fuel cell system. Balcombea et al (2015) investigated the impacts associated with the integrated system involving three CHP technologies.…”
Section: Introductionmentioning
confidence: 99%
“…Suzuki et al (2007) implemented a residential cogeneration system. Kim et al (2014) developed an economic and environmental assessment model for selecting the optimal implementation strategy of the fuel cell system focusing on building energy policy. For additional technologies, Hong et al (2014) implemented a fuel cellbased combined heat and power system for a multi-family housing complex located in Seoul, South Korea.…”
Section: Introductionmentioning
confidence: 99%