An early multicenter experience of the novel high-density star-shaped mapping catheter in complex arrhythmias

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 18 publications
0
5
0
Order By: Relevance
“…In comparison to other panoramic mapping systems, the CartoFinder system created global activation propagation maps using local activation times obtained through annotation of atrial signals 12,16,17,30 . Combined with the use of recently developed high‐density diagnostic catheters and identification of appropriate patients to avoid over‐ablation, CartoFinder had the potential to provide an effective patient‐specific ablation target based on high‐resolution AF activation maps of the RA and LA 11,16,17,32,33 …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In comparison to other panoramic mapping systems, the CartoFinder system created global activation propagation maps using local activation times obtained through annotation of atrial signals 12,16,17,30 . Combined with the use of recently developed high‐density diagnostic catheters and identification of appropriate patients to avoid over‐ablation, CartoFinder had the potential to provide an effective patient‐specific ablation target based on high‐resolution AF activation maps of the RA and LA 11,16,17,32,33 …”
Section: Discussionmentioning
confidence: 99%
“…12,16,17,30 Combined with the use of recently developed highdensity diagnostic catheters and identification of appropriate patients to avoid over-ablation, CartoFinder had the potential to provide an effective patient-specific ablation target based on high-resolution AF activation maps of the RA and LA. 11,16,17,32,33 Study limitations included the fact that this was a non-randomized, non-blinded study. In addition, as the study was conducted with an ear-…”
Section: Discussionmentioning
confidence: 99%
“…However, to avoid any misleading interpretation of the underlying circuit, accurate and high-density mapping of investigated atrial chambers is required to account for almost 90% of the tachycardia cycle length and thereby avoiding missing mapping segments potentially due to non-annotated low-amplitude and fragmented electrograms as low as 0.03–0.05 mV [ 27 ]. In this setting, the recent development of new tools, such as Octaray TM system (Biosense Webster Inc., Irvine, CA, USA) and the Ensite TM Omnipolar Technology (OT) (Abbott, Chicago, IL, USA) might allow for even better results [ 62 , 63 , 64 ], provided that the multitude of signals collected is correctly acquired and interpreted.…”
Section: The Winding Path To Improve the Procedures And The Overall C...mentioning
confidence: 99%
“…Recently, a new OCTARAY ® mapping catheter (Biosense Webster, Diamond Bar, CA, USA) was commercially launched. 6,7 This OCTARAY catheter has 48 electrodes arranged on eight radiating splines, and is an improved version of PENTARAY ® catheter (Biosense Webster) which has 20 electrodes arranged on five5 radiating splines. The new catheter is designed to enable rapid, high-density mapping, with precise signal recording via the small electrodes and improved unipolar signal quality due to the indifferent electrode located at the center of radiating splines.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, a new OCTARAY ® mapping catheter (Biosense Webster, Diamond Bar, CA, USA) was commercially launched 6,7 . This OCTARAY catheter has 48 electrodes arranged on eight radiating splines, and is an improved version of PENTARAY ® catheter (Biosense Webster) which has 20 electrodes arranged on five5 radiating splines.…”