2014
DOI: 10.1088/1742-6596/489/1/012075
|View full text |Cite
|
Sign up to set email alerts
|

An automatic dose verification system for adaptive radiotherapy for helical tomotherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…These software systems have been designed with the aim to streamline the ART workflow and reduce the need for human intervention, by executing automated dose calculations on new CBCT‐based imaging. New contours are derived either through the propagation of planning volumes using DIR, 93 , 94 , 95 , 96 automated delineation, 97 or by a combination of both. 98 In the next phase, dose‐volume histograms (DVH) are calculated on the new contours.…”
Section: Pitfalls For Clinical Implementationmentioning
confidence: 99%
“…These software systems have been designed with the aim to streamline the ART workflow and reduce the need for human intervention, by executing automated dose calculations on new CBCT‐based imaging. New contours are derived either through the propagation of planning volumes using DIR, 93 , 94 , 95 , 96 automated delineation, 97 or by a combination of both. 98 In the next phase, dose‐volume histograms (DVH) are calculated on the new contours.…”
Section: Pitfalls For Clinical Implementationmentioning
confidence: 99%
“…The automatic platform for adaptive therapy developed by 21 st Century Oncology (Madison,WI) [16] was used to monitor the delivered dose using daily setup Megavoltage CT images (MVCT) acquired from the Tomotherapy units installed in the Cliniques Universitaires Saint-Luc, Brussels, Belgium. Figure 1 illustrates the process to automatically flag the candidate patients for ART.…”
Section: Automatic Decision Support Software For Artmentioning
confidence: 99%
“…In the last few years, several companies have launched commercial software that automatically perform the dose calculation in the new image and generate new contours. The new contours are obtained either by propagating the planning volumes using deformable image registration, [13][14][15][16][17] by using automatic (e.g. atlas-based or machine learning) segmentation models on the new image, 18 or by a combination of both.…”
Section: Introductionmentioning
confidence: 99%