An automated synthesis method for 68Ga-labelled ubiquicidin 29–41

Abstract: Published methods for radiolabelling of 1,4,7-triazacyclononane-1,4,7-triacetic acid ubiquicidin (NOTA-UBI) 29-41 to date describe manual or kit-based procedures. The purpose of this study was to develop an automated synthesis method for the synthesis of [ 68 Ga]Ga-NOTA-UBI. NOTA-UBI was successfully labelled with gallium-68 using the three different automated procedures. The use of radical scavengers to improve radiochemical purity is also discussed. The automated procedures showed a high degree of robustness… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
18
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 7 publications
(20 citation statements)
references
References 38 publications
0
18
0
Order By: Relevance
“…The entire method is preprogramed on the system as a standard peptide labeling method with gallium‐68 (ABX advanced biochemical compounds GmbH [Radeberg, Germany]). The system eluted the 68 Ge/ 68 Ga generator with 10‐ml 0.6M HCl and purified it with a PS‐H + ‐matrix‐based cation exchange chromatography as described previously 15,16 . Purified [ 68 Ga]GaCl 3 was recovered from the cartridge using a 5.0M sodium chloride solution and added to the reaction vial containing 10 μg of PSMA‐11 dissolved in HEPES buffer.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The entire method is preprogramed on the system as a standard peptide labeling method with gallium‐68 (ABX advanced biochemical compounds GmbH [Radeberg, Germany]). The system eluted the 68 Ge/ 68 Ga generator with 10‐ml 0.6M HCl and purified it with a PS‐H + ‐matrix‐based cation exchange chromatography as described previously 15,16 . Purified [ 68 Ga]GaCl 3 was recovered from the cartridge using a 5.0M sodium chloride solution and added to the reaction vial containing 10 μg of PSMA‐11 dissolved in HEPES buffer.…”
Section: Methodsmentioning
confidence: 99%
“…The automated synthesis unit is programmed to rinse the SEP‐Pak C‐18 cartridge with 2 ml of 50% v/v water and ethanol, and the final volume of the reaction mixture is 17 ml. A calculation was done to ensure that a safe amount of ethanol is in the final product because the acceptable threshold of ethanol (10% v /v) can never be exceeded 15 …”
Section: Methodsmentioning
confidence: 99%