2008
DOI: 10.1134/s0020441208020279
|View full text |Cite
|
Sign up to set email alerts
|

An automated setup for determining the kinematic viscosity of metal melts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
8
0
5

Year Published

2010
2010
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 50 publications
(13 citation statements)
references
References 3 publications
0
8
0
5
Order By: Relevance
“…The master alloy was prepared from carbonyl iron powder and electrolytic chromium in an Al 2 O 3 crucible maintained isother mally in a vacuum induction furnace at 1700°C under a pressure of 5 × 10 -3 Pa for 30 min. According to the chemical analysis data of samples before and after the The kinematic viscosity, ν, of liquid Fe-Cr alloys was measured by means of damping torsional oscilla tions of a crucible with the melt in the manner pro posed by Shvidkovskii [23]. All measurements were performed in a protective atmosphere of purified helium in the following mode: heating from the melt ing point to 1680°С and subsequent cooling with an increment of 10°С including isothermal exposures at each temperature for 20 min.…”
Section: Methodsmentioning
confidence: 99%
“…The master alloy was prepared from carbonyl iron powder and electrolytic chromium in an Al 2 O 3 crucible maintained isother mally in a vacuum induction furnace at 1700°C under a pressure of 5 × 10 -3 Pa for 30 min. According to the chemical analysis data of samples before and after the The kinematic viscosity, ν, of liquid Fe-Cr alloys was measured by means of damping torsional oscilla tions of a crucible with the melt in the manner pro posed by Shvidkovskii [23]. All measurements were performed in a protective atmosphere of purified helium in the following mode: heating from the melt ing point to 1680°С and subsequent cooling with an increment of 10°С including isothermal exposures at each temperature for 20 min.…”
Section: Methodsmentioning
confidence: 99%
“…Kinematic viscosity, (m), was measured by the method of damping torsional vibrations of the corundum crucible filled with the melt [15,16]. The measurements were performed during heating and cooling the melt, the range of the temperature being from the melting temperature to 1890 K. The temperature changed gradually with the step equal to 15 K. The melt was isothermally exposed for 20 min at each point.…”
Section: Methodsmentioning
confidence: 99%
“…При этом термозависимости (политермы) ν = Ψ( ) цикла нагрева и охлаждения образца позволяют вы-делять характерные температурные точки и гисте-резисные характеристики этого цикла. Для высоко-температурных исследований сплавов ( ≥ 1000 °С) [1] используют немногие способы измерения вязко-сти, преимущественно фотометрическое определение ν = Ψ( ), основанное на зависимости ν ~ δ 2 . Расчет ло-гарифмического декремента затухания δ производят по значениям амплитуд А i : δ = ln (A i / A i + 1 ) периодов T i , временных значений t i : δ = -1/n {ln(t 0 / t n )}, числа n i кру-тильных колебаний тигля с расплавом, скорости про-хождения положения равновесия: δ = -1/n {ln(V 0 / V n )}.…”
unclassified
“…Измеряют временные моменты t 1 , t 2 засветки фотосенсоров (например, по передним фронтам) и раз-ность между ними Δt = τ при прохождении отраженным световым лучом линейного отрезка ΔА вблизи точки смены полярности колебания амплитуды А i . Точность определения ν составляет единицы процентов [1].…”
unclassified
See 1 more Smart Citation