An Automated Assay for Growth Differentiation Factor 15

Abstract: Background: Growth differentiation factor 15 (GDF-15) can serve as a biomarker for cardiovascular disease burden and risk. We evaluated a new, fully automated electrochemiluminescence immunoassay for measuring GDF-15. Methods: Six laboratories independently characterized the Elecsys ® GDF-15 assay (Roche Diagnostics) under routine conditions. Within-run precision (repeatability), within-laboratory precision (intermediate precision), and betweenlaboratory precision (reproducibility) were assessed. Plasma-serum … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
24
1
3

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(29 citation statements)
references
References 30 publications
(58 reference statements)
1
24
1
3
Order By: Relevance
“…Plasma GDF-15 was measured by a different method in the healthy control group. There has however been published a study that compares different methods to measure GDF-15, and it shows a good correlation between the two methods [18]. We are therefore confident that the comparison is reliable.…”
Section: Discussionmentioning
confidence: 71%
See 1 more Smart Citation
“…Plasma GDF-15 was measured by a different method in the healthy control group. There has however been published a study that compares different methods to measure GDF-15, and it shows a good correlation between the two methods [18]. We are therefore confident that the comparison is reliable.…”
Section: Discussionmentioning
confidence: 71%
“…According to a recent study [18], there is a good correlation between the two different methods of measuring GDF-15 in plasma.…”
Section: Bloodmentioning
confidence: 98%
“…GDF‐15 levels appear somewhat lower than plasma concentrations of apparently healthy individuals determined by IRMA or the Roche assay in other studies, which may be based on the nature of a manual technique or that the ELISA method seems to results in lowest GDF‐15 values compared to IRMA or the Elecsys® measurements . Altogether a very good correlation was shown for the ELISA method with the just recently available first clinically approved Elecsys® assay (Roche Diagnostics) …”
Section: Discussionmentioning
confidence: 99%
“…levels with all-cause mortality in unselected treatment-naïve cancer patients according to tumour site (n = 555) or the Elecsys® measurements. 23 Altogether a very good correlation was shown for the ELISA method with the just recently available first clinically approved Elecsys® assay (Roche Diagnostics). 23…”
Section: T a B L E 3 Association Of Gdf-15mentioning
confidence: 99%
“…Czynniki wpływające na stężenie czynnika różnicowania wzrostu 15 (GDF-15, growth differentiation factor 15) i potencjalny wpływ tego biomarkera na mięsień sercowy (na podstawie [14,15] umożliwiła zautomatyzowanie oznaczania GDF-15, a tym samym jego szersze wykorzystanie [17]. Przeważająca liczba dotychczasowych badań wskazuje na trzy przedziały ryzyka sercowo-naczyniowego: stężenia poniżej 1200 ng/l odpowiadają niskiemu ryzyku (górna granica wartości referencyjnych dla osób zdrowych), 1200-1800 ng/lumiarkowanemu (przeciętnemu) ryzyku, a przekraczające 1800 ng/l -wysokiemu ryzyku [18].…”
Section: Znaczenie Biologiczne Gdf-15unclassified