2012
DOI: 10.1016/j.ejogrb.2012.07.021
|View full text |Cite
|
Sign up to set email alerts
|

An audit of using the H Pipelle for endometrial sampling at outpatient hysteroscopy and literature review comparison with the Pipelle de Cornier

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 24 publications
0
8
0
Order By: Relevance
“…The Pipelle H optimizes endometrium sampling during the procedure of diagnostic hysteroscopy (37,38). The Pipelle H is twice longer (50 cm), but has the same external and internal diameters as the genuine Pipelle de Cornier (29). The device enables appropriate suction to collect a sufficient volume of endometrial tissue.…”
Section: Pipelle Sampling Device and Its Modificationsmentioning
confidence: 99%
See 1 more Smart Citation
“…The Pipelle H optimizes endometrium sampling during the procedure of diagnostic hysteroscopy (37,38). The Pipelle H is twice longer (50 cm), but has the same external and internal diameters as the genuine Pipelle de Cornier (29). The device enables appropriate suction to collect a sufficient volume of endometrial tissue.…”
Section: Pipelle Sampling Device and Its Modificationsmentioning
confidence: 99%
“…Since the beginning of the ’80s, hysteroscopies have been a way to provide clinicians with direct visualization of the cervical canal and the uterine cavity ( 28 ). Hysteroscopy is acknowledged to be very useful and informative procedure of uterine cavity assessment for endometrial and intrauterine abnormalities associated with both pre- and postmenopausal abnormal uterine bleeding ( 29 , 30 ). Nowadays, the investigation is usually done in an outpatient setting.…”
Section: Overview On Diagnostic Modalities For Detection Of Endometrial Carcinomamentioning
confidence: 99%
“…2. "Pipelle Н" has the same outer and inner diameters as "Pipelle de cornier" and is 50 cm long [12]. "Pipelle H" device was developed at the Royal Free Hospital in London for histological sampling during routine hysteroscopies.…”
Section: The Main Findings and Resultsmentioning
confidence: 99%
“…Endometrial tissue samples were obtained by pipelle sampling with inner membrane in the secretory phase including two endometrial gland cells and stromal cells. 15 …”
Section: Methodsmentioning
confidence: 99%