IEEE Nuclear Science Symposuim &Amp; Medical Imaging Conference 2010
DOI: 10.1109/nssmic.2010.5874056
|View full text |Cite
|
Sign up to set email alerts
|

An ASIC for SiPM/MPPC readout

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 7 publications
0
12
0
Order By: Relevance
“…A strong case has been made for the adoption of SPECT/MRI for preclinical use. 14 In most of the experimental synchronous preclinical SPECT/MRI systems under study, arrays of CdTe or CdZnTe (CZT) gamma detectors are employed, 21,22 Similar solid-state technology is finding increasing use in clinical SPECT systems being used for cardiac imaging, 23,24 scintimammography 25 and, more recently, whole-body SPECT imaging. 26 As regards compatibility with MRI, preliminary investigations on CdTe and CZT have shown that a shift of the signal charge inside the detector caused by Lorentz forces takes place and this phenomenon requires correction to improve the detector response so as to achieve a high resolution.…”
Section: Spect Detectors For Simultaneous Spect/mrimentioning
confidence: 99%
“…A strong case has been made for the adoption of SPECT/MRI for preclinical use. 14 In most of the experimental synchronous preclinical SPECT/MRI systems under study, arrays of CdTe or CdZnTe (CZT) gamma detectors are employed, 21,22 Similar solid-state technology is finding increasing use in clinical SPECT systems being used for cardiac imaging, 23,24 scintimammography 25 and, more recently, whole-body SPECT imaging. 26 As regards compatibility with MRI, preliminary investigations on CdTe and CZT have shown that a shift of the signal charge inside the detector caused by Lorentz forces takes place and this phenomenon requires correction to improve the detector response so as to achieve a high resolution.…”
Section: Spect Detectors For Simultaneous Spect/mrimentioning
confidence: 99%
“…The gain was determined from the distance between pedestal and the first photopeak and between adjacent photopeaks. We took advantage of our previous experience with similar measurements using front-end and readout electronics based on an Application Specific Integrated Circuit (ASIC) tailored to SiPM readout and developed by our research group in collaboration with GM-IDEAS, as described in our earlier publications [8], [9], [10].…”
Section: Characterization Of the Nuv-sipm Sensorsmentioning
confidence: 99%
“…This was made possible by the development of a custom ASIC (Application Specific Integrated Circuit), with 64 channels, carried out in collaboration with GM-Ideas, Norway [20]. A readout board -developed by our group [21] -with a 16 bit ADC and interfaced via the USB2 protocol to a PC, records both the pulse height of each fired channel and a time stamp generated when the signal crosses an individually adjustable threshold.…”
Section: Prototype Developmentmentioning
confidence: 99%