2021
DOI: 10.3390/polym13203552
|View full text |Cite
|
Sign up to set email alerts
|

An Artificial Lens Capsule with a Lens Radial Stretching System Mimicking Dynamic Eye Focusing

Abstract: Presbyopia is a common eye disorder among aged people which is attributed to the loss of accommodation of the crystalline lens due to the increasing stiffness. One of the potential techniques to correct presbyopia involves removing the lens substance inside the capsule and replacing it with an artificial lens. The development of such devices, e.g., accommodating intraocular lenses (AIOLs), relies on the understanding of the biomechanical behaviour of the lens capsule and the essential design verification ex vi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 50 publications
0
9
0
Order By: Relevance
“…The relative pressure from the lens substance was defined to be 4 to 6 mmHg (of 0.5 to 0.8 kPa) under accommodative stimulation [24,42], whilst the resisting pressure of the lens capsule can reach as high as 40 mmHg (of 5.0 kPa) [48]. A high pressure value (of 2.0 kPa) of the ALC was deduced by a reverse approach with FEA to be compensated for its high thickness (of 150 µm) in contrast to the human capsule (of 5 to 30 µm), providing the insight into the over-inflation status in a previous study [28]. Compared to the studies using a flat surface as the initial shape of the human capsule, the reference state of the ALC was defined to be the moulded shape, significantly diminishing the pretension effect of materials before exerting stretch.…”
Section: Discussionmentioning
confidence: 68%
See 4 more Smart Citations
“…The relative pressure from the lens substance was defined to be 4 to 6 mmHg (of 0.5 to 0.8 kPa) under accommodative stimulation [24,42], whilst the resisting pressure of the lens capsule can reach as high as 40 mmHg (of 5.0 kPa) [48]. A high pressure value (of 2.0 kPa) of the ALC was deduced by a reverse approach with FEA to be compensated for its high thickness (of 150 µm) in contrast to the human capsule (of 5 to 30 µm), providing the insight into the over-inflation status in a previous study [28]. Compared to the studies using a flat surface as the initial shape of the human capsule, the reference state of the ALC was defined to be the moulded shape, significantly diminishing the pretension effect of materials before exerting stretch.…”
Section: Discussionmentioning
confidence: 68%
“…Experimental and numerical studies have shown a single or multiple linear relationship between the stretching force and radial stretch [14,[17][18][19]37,68]. The multilinear correlation was attributed to the influence of testing environmental factors (mobilisation, pretension, and dynamic effects) during the stretching process by a previous study [28], which was further validated by the linearity and accordance of FEA by extracting the force contribution only from the stretch of the ALC. The overall contraction force of the human lens ranged from 3 g to 13 g as assessed by ex vivo stretching tests [14,[17][18][19]69], which is slightly reduced by the extraction of lens substance [14,18].…”
Section: Discussionmentioning
confidence: 69%
See 3 more Smart Citations