2015
DOI: 10.1080/1448837x.2015.1092926
|View full text |Cite
|
Sign up to set email alerts
|

An approach for establishing key parameter system and evaluating the state of transmission line

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…Very common among these connection on the field includes, star-star, delta-delta, star-delta, delta-star, open-delta and Scott connection [2] , [3] , [4] , [5] , [6] . In distribution substations, the delta-star connection transformers are commonly used by service providers in making electricity supply available to their prospective customers [2] , [3] , [4] , [5] , [6] , [7] , [8] , [9] , [10] , [11] , [12] . If applied as step-up transformer, the secondary compartment will be star connected; But when applied as step-down transformer, secondary compartment will be star connected because the supply of electricity to customers will require a grounded neutral (Primary distribution) [2] , [3] , [4] , [5] , [6] .…”
Section: Methods Detailsmentioning
confidence: 99%
See 1 more Smart Citation
“…Very common among these connection on the field includes, star-star, delta-delta, star-delta, delta-star, open-delta and Scott connection [2] , [3] , [4] , [5] , [6] . In distribution substations, the delta-star connection transformers are commonly used by service providers in making electricity supply available to their prospective customers [2] , [3] , [4] , [5] , [6] , [7] , [8] , [9] , [10] , [11] , [12] . If applied as step-up transformer, the secondary compartment will be star connected; But when applied as step-down transformer, secondary compartment will be star connected because the supply of electricity to customers will require a grounded neutral (Primary distribution) [2] , [3] , [4] , [5] , [6] .…”
Section: Methods Detailsmentioning
confidence: 99%
“…In power generation analysis, the magnitude and displacement of the 3 phase output are observed to be approximately balanced compared to what is obtainable in both distribution and transmission networks [7] , [8] , [9] , [10] . The aftermath of this is that, unbalanced Voltage for example deteriorates the operation and performance of electrical equipment such as distribution transformers [7] , [8] , [9] , [10] , [11] , [12] , [13] , [14] , [15] , [16] . Consequently, this paper aims at analysing some three phase distribution transformers in a network of a power utility company having an unbalance voltage conditions.…”
Section: Methods Detailsmentioning
confidence: 99%
“…The literature [12] summarizes the characteristics of transmission and substation equipment condition monitoring data, and completes data cleaning of the original condition information by constructing time series models, estimating model parameters, identifying abnormal data types, and repairing and correcting data. The literature [13] uses big data analysis methods based on time series analysis and unsupervised learning to monitor abnormal data and test and analyze the transmission and substation status equipment. The above data cleaning methods only consider the anomalies of a single sequence and ignore the correlation between the sequences of power data state quantities.…”
Section: Introductionmentioning