2023
DOI: 10.1111/anec.13054
|View full text |Cite
|
Sign up to set email alerts
|

An annotated ventricular tachycardia (VT) alarm database: Toward a uniform standard for optimizing automated VT identification in hospitalized patients

Abstract: Background: False ventricular tachycardia (VT) alarms are common during in-hospital electrocardiographic (ECG) monitoring. Prior research shows that the majority of false VT can be attributed to algorithm deficiencies. Purpose:The purpose of this study was: (1) to describe the creation of a VT database annotated by ECG experts and (2) to determine true vs. false VT using a new VT algorithm created by our group. Methods:The VT algorithm was processed in 5320 consecutive ICU patients with 572,574 h of ECG and ph… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 37 publications
0
6
0
Order By: Relevance
“…All available ECG and physiological waveform data were collected using a closed network system that connected all 77 bedside ICU monitors (Solar 8000i Version 5.4 software, GE Healthcare, Milwaukee, WI) via a gateway system. 16 Data were sent to a secure, hospital-approved server maintained by our research laboratory. The following data were collected from each ICU monitor: (1) all available waveforms (ECG, invasive arterial blood pressure [BP], central venous pressure, intracranial pressure, plethysmograph [SpO 2 ]); (2) vital signs (heart rate, noninvasive BP, respiratory rate); (3) alarm settings (crisis, warning, or advisory and message/technical); and (4) audible and inaudible alarms.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…All available ECG and physiological waveform data were collected using a closed network system that connected all 77 bedside ICU monitors (Solar 8000i Version 5.4 software, GE Healthcare, Milwaukee, WI) via a gateway system. 16 Data were sent to a secure, hospital-approved server maintained by our research laboratory. The following data were collected from each ICU monitor: (1) all available waveforms (ECG, invasive arterial blood pressure [BP], central venous pressure, intracranial pressure, plethysmograph [SpO 2 ]); (2) vital signs (heart rate, noninvasive BP, respiratory rate); (3) alarm settings (crisis, warning, or advisory and message/technical); and (4) audible and inaudible alarms.…”
Section: Methodsmentioning
confidence: 99%
“…In addition, we used all available ECG waveforms, SpO 2 , and invasive arterial BP waveforms to process the new VT algorithm developed by our group. 16 …”