2009
DOI: 10.1016/j.snb.2008.09.051
|View full text |Cite
|
Sign up to set email alerts
|

An amperometric glucose biosensor fabricated with Pt nanoparticle-decorated carbon nanotubes/TiO2 nanotube arrays composite

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
89
1

Year Published

2010
2010
2016
2016

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 216 publications
(91 citation statements)
references
References 35 publications
1
89
1
Order By: Relevance
“…Figure 3d displays the amperometric responses on GOx/PtNPs-TH-MWCNTs (r TH-Pt = 0.10 : 1)/ Au at 0.5 V to successive additions of glucose, and the time required to reach 95 % of each steady-state response is within 5 s. The GOx/PtNPs-TH-MWCNTs (r TH-Pt = 0.10 : 1)/Au electrode exhibits a linear response to glucose in the concentration range from 1.65 mM to 11.1 mM (r 2 = 0.999), with a sensitivity of 0.14 A M À1 cm À2 and a detection limit of 0.05 mM (S/N = 3). The sensitivity here is probably the greatest one for first-generation GOx-based glucose biosensing to date [35][36][37][38].…”
Section: à2mentioning
confidence: 98%
See 1 more Smart Citation
“…Figure 3d displays the amperometric responses on GOx/PtNPs-TH-MWCNTs (r TH-Pt = 0.10 : 1)/ Au at 0.5 V to successive additions of glucose, and the time required to reach 95 % of each steady-state response is within 5 s. The GOx/PtNPs-TH-MWCNTs (r TH-Pt = 0.10 : 1)/Au electrode exhibits a linear response to glucose in the concentration range from 1.65 mM to 11.1 mM (r 2 = 0.999), with a sensitivity of 0.14 A M À1 cm À2 and a detection limit of 0.05 mM (S/N = 3). The sensitivity here is probably the greatest one for first-generation GOx-based glucose biosensing to date [35][36][37][38].…”
Section: à2mentioning
confidence: 98%
“…) [33]. The sensor reached 95 % of the steady-state current within 5 s, allowing the convenient quantification of H 2 O 2 .…”
Section: à2mentioning
confidence: 99%
“…Additionally bio-devices with noble metal or nanomaterials, such as gold (Au), platinum (Pt) and Carbon nanotubes (CNTs) on the surface, are often used in bio-technology by exerting good functions like detecting antibody [1] or catalytic reaction [2]. And, the nano-structuration technologies for functional surface are also required to increase these functions [3]. Therefore, the process for the functional surface is importance in the fabrication of bio-and medical devices.…”
Section: Introductionmentioning
confidence: 99%
“…Additionally bio-devices with noble metal or nanomaterials, such as gold (Au), platinum (Pt) and Carbon nanotubes (CNTs) on the surface, are often used in bio-technology by exerting good functions like detecting antibody [1] or catalytic reaction [2]. And, the nano-structuration technologies for functional surface are also required to increase these functions [3]. Therefore, the process for the functional surface is importance in the fabrication of bio-and medical devices.…”
Section: Introductionmentioning
confidence: 99%