“…A connection to a common dc grid with a voltage of few kVs is adequate for low power systems. For higher power systems, a dc-dc converter with a high-frequency insulating transformer can be used in order to boost the voltage to higher values [16].…”
Section: Index Terms-mentioning
confidence: 99%
“…This value of K r is set in order to have a phase shift less than 3 deg in the closed loop transfer function. The resulting cross-over frequency of the current loop and the phase margin calculated by (16) are 344 Hz and 51.3 deg respectively, whereas the gain and the phase of the closed loop transfer function at ω=ω 0 are 1.006 p.u. and 2.86 deg respectively, which confirm the good tracking capability for the harmonic reference signals at the resonance frequency.…”
Section: Torque Control With Pi-r Current Controllersmentioning
“…A connection to a common dc grid with a voltage of few kVs is adequate for low power systems. For higher power systems, a dc-dc converter with a high-frequency insulating transformer can be used in order to boost the voltage to higher values [16].…”
Section: Index Terms-mentioning
confidence: 99%
“…This value of K r is set in order to have a phase shift less than 3 deg in the closed loop transfer function. The resulting cross-over frequency of the current loop and the phase margin calculated by (16) are 344 Hz and 51.3 deg respectively, whereas the gain and the phase of the closed loop transfer function at ω=ω 0 are 1.006 p.u. and 2.86 deg respectively, which confirm the good tracking capability for the harmonic reference signals at the resonance frequency.…”
Section: Torque Control With Pi-r Current Controllersmentioning
“…Since no intermediate reactive devices are required, a MC allows for a very compact design. In addition to these advantages, its low cost and high power density have made MC an attractive solution for special applications such as compact drives, drives in hostile environments, military applications [37], aerospace [38], and renewable energy [39][40][41].…”
“…This layout is interesting for distributed generation systems [25]- [26] and dc micro-grids [27]- [28], where wind turbines, solar panels, bio-fuel, as well as storage systems could be effectively integrated by means of a common dc-bus. A dc input is also suitable to feed the dc-ac converter and the medium frequency boost transformer in high voltage dc transmission lines [29]- [30].…”
Abstract-This paper deals with a new conversion topology for DFIGs suitable for wind energy conversion systems integrated in micro-grids. It consists of a DFIG which is fed by a PWM converter on the rotor and with the stator connected to a dc grid through a diode rectifier. In this configuration, the stator diode rectifier and the rotor-side inverter share the same dc-bus, so that the conventional grid-side inverter is avoided. Since only a diode rectifier designed for the full power and a reduced power inverter are required, this layout allows a cheap and effective integration of the DFIG with other generating and storage systems connected to the same dc-bus. A simple control technique suitable to regulate the power delivered to the dc grid is proposed. The scheme is based on the regulation of the amplitude of a suited fraction of the rotor flux linkage: the optimal value of this fraction is theoretically deduced in order to minimize the DFIG derating due to the current harmonics. The effectiveness of the proposed control is proven by simulations and experimental tests.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.