2013
DOI: 10.1111/j.1525-1403.2012.00457.x
|View full text |Cite
|
Sign up to set email alerts
|

An Algorithm for Management of Deep Brain Stimulation Battery Replacements: Devising a Web-Based Battery Estimator and Clinical Symptom Approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
26
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 34 publications
(27 citation statements)
references
References 13 publications
1
26
0
Order By: Relevance
“…Some subjects experienced discomfort in response to intraoperative stimulation at the clinically programmed stimulation amplitude, and the voltage was decreased to the maximum tolerable level for these individuals (3/9 subjects). IPGs near end-of-life often require an increased stimulation amplitude to compensate for lower current output due to decreased battery supply voltage [Montuno et al, 2013]. Therefore, intraoperative stimulation at the clinically programmed voltage may have caused discomfort due to delivery of more current than the depleted IPG produced.…”
Section: Methodsmentioning
confidence: 99%
“…Some subjects experienced discomfort in response to intraoperative stimulation at the clinically programmed stimulation amplitude, and the voltage was decreased to the maximum tolerable level for these individuals (3/9 subjects). IPGs near end-of-life often require an increased stimulation amplitude to compensate for lower current output due to decreased battery supply voltage [Montuno et al, 2013]. Therefore, intraoperative stimulation at the clinically programmed voltage may have caused discomfort due to delivery of more current than the depleted IPG produced.…”
Section: Methodsmentioning
confidence: 99%
“…Recent advances in target selection may reduce this latency to days in the case of depression (28). There is a risk of device malfunction (29), and in all cases, neurostimulator replacement may be necessary (30), provided the DBS patient outlives the device (i.e., typically two to five years for device replacement and seven to ten years for rechargeable batteries).…”
mentioning
confidence: 99%
“…[10][11][12][13][14] • At this time, there is no evidence that other groups of patients are at risk for life-threatening symptoms from DBS cessation, but this could change with the course of time. • Though not life-threatening per se, severe symptoms upon DBS cessation due to battery depletion 15 should be evaluated for urgent surgery on a case-by-case basis, and in an effort to minimize hospitalizations or evaluations in the emergency department.…”
Section: Dbs For Movement Disorders Recommendationsmentioning
confidence: 99%