An advanced physiological data logger for medical imaging applications

Abstract: The interest of physiological data sensing and recording using wireless body sensor network has increased in recent years due to the advancement of miniature and portable electronic devices. In this study, the design of a portable and rechargeable data logger with high data rate multiple wireless connectivity (Bluetooth and 2.4-GHz radio frequency) is discussed. The data are logged in micro secure digital (SD) cards and can be transferred to PC or Smartphone using SD card reader, USB interface, or Bluetooth wi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 25 publications
0
7
0
Order By: Relevance
“…However, when the distance increased to 10 meters, we noticed that transmission rate was affected, with 80% of data successfully transmitted. Since, the data logger is wearable and generally worn around the waist in practice, the distance between a swallowed capsule and the data logger is generally about 0.3 meter [52]. Therefore, we expect our prototype to work at 2.4 GHz spectrum with no loss of data during communication.…”
Section: Wireless Communicationmentioning
confidence: 99%
“…However, when the distance increased to 10 meters, we noticed that transmission rate was affected, with 80% of data successfully transmitted. Since, the data logger is wearable and generally worn around the waist in practice, the distance between a swallowed capsule and the data logger is generally about 0.3 meter [52]. Therefore, we expect our prototype to work at 2.4 GHz spectrum with no loss of data during communication.…”
Section: Wireless Communicationmentioning
confidence: 99%
“…In the current scenario, Bluetooth is the most suitable option because of its high bandwidth and support on many smartphone platforms. In [ 42 ], a high bit-rate data logger and its connectivity through Bluetooth are presented. A Bluetooth transreceiver [ 43 ] is connected with an IRU microcontroller in WCE.…”
Section: Framework Of the Proposed Systemmentioning
confidence: 99%
“…This design does not include an internal storage memory. In [12], an advanced physiological data logger for medical imaging applications was designed. In the design, a 4MB SD card was used to store biomedical data.…”
Section: Related Workmentioning