2011
DOI: 10.1007/s10765-011-0941-y
|View full text |Cite
|
Sign up to set email alerts
|

An Adiabatic Calorimeter for the Realization of the ITS-90 in the Cryogenic Range at the LNE-CNAM

Abstract: The LNE-CNAM, in cooperation with the IPN, has recently developed a new cryogen-free adiabatic calorimeter, to realize the International Temperature Scale of 1990 (ITS-90) in the temperature range between 6 K and 84 K. The new calorimeter, cooled by a closed-cycle Gifford-McMahon refrigerator, is equipped with three thermal shields and two separate vacuum chambers, to minimize the effect of parasitic heat fluxes. The inner adiabatic chamber can accommodate either a multi-compartment cell--containing the triple… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(13 citation statements)
references
References 5 publications
(8 reference statements)
0
13
0
Order By: Relevance
“…In order to estimate the quality of the improved adiabatic calorimeter, a characterization study is carried out as in references [4,7,8]. There are three main thermal factors of the study describing the thermal behaviour…”
Section: Thermal Study Of the Calorimetermentioning
confidence: 99%
See 2 more Smart Citations
“…In order to estimate the quality of the improved adiabatic calorimeter, a characterization study is carried out as in references [4,7,8]. There are three main thermal factors of the study describing the thermal behaviour…”
Section: Thermal Study Of the Calorimetermentioning
confidence: 99%
“…The heat capacity of the compartement has a static thermal behaviour while its values did not change by varing the optimum conditions, which was determined by measuring the amount of heat energy required to increase the temperature of the compartment by a known amount [8,9]. The energy supplied to the cell was determined from the electrical power applied to the heater around the cell:…”
Section: Heat Capacitymentioning
confidence: 99%
See 1 more Smart Citation
“…In order to estimate the measurement accuracy of the adiabatic calorimeter, a characterization similar to that presented in [7] was realized, measuring the heat capacity C C of the cell and the thermal resistance R S between the cell and the adiabatic shield, at temperatures close to the TPW.…”
Section: Calorimeter Characterizationmentioning
confidence: 99%
“…NIS has made use of the experience of the LNE-CNAM [2][3][4][5] to build the calorimeter that would work with the existed facilities.…”
Section: Introductionmentioning
confidence: 99%