2022
DOI: 10.1016/j.phro.2022.01.005
|View full text |Cite
|
Sign up to set email alerts
|

An adaptive planning strategy in carbon ion therapy of pancreatic cancer involving beam angle selection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 35 publications
(38 reference statements)
0
2
0
Order By: Relevance
“…We also found a highly robust dose distribution of BC_gantry with TM, and the dose degradation in CTV V95% was very limited (mean value: 3.8%), which was close to that of the adaptive method (mean value: 2.1%) reported in a previous study [28]. Adaptive therapy has been verified as the most effective method for improving the robustness of CIRT plans [28][29][30]. However, rapid online dose verification and quality assurance systems are still challenging.…”
Section: Discussionsupporting
confidence: 85%
“…We also found a highly robust dose distribution of BC_gantry with TM, and the dose degradation in CTV V95% was very limited (mean value: 3.8%), which was close to that of the adaptive method (mean value: 2.1%) reported in a previous study [28]. Adaptive therapy has been verified as the most effective method for improving the robustness of CIRT plans [28][29][30]. However, rapid online dose verification and quality assurance systems are still challenging.…”
Section: Discussionsupporting
confidence: 85%
“…Adaptive planning is an increasing concern in particle therapy [35] . However, the optimal method has not fully been established [36] , [37] . Through recalculation on vCTs, it may be necessary to conduct re-planning at the beginning of treatment in some cases.…”
Section: Discussionmentioning
confidence: 99%
“…27,148 These and many other developments promise increased process efficiency and decreased facility operational costs, coupled with improving accuracy and personalisation of PT. 22,27,31,144,145,148 They include accelerator control efficiency, higher dose rates, faster energy and beamline switching, flexible beam direction selection, and beam verification and measurement equipment and methods, as well as treatment planning algorithms and software systems, online imaging systems and image-guidance, 22,[150][151][152] motion management methods, 24,153,154 adaptive CIRT 149,155 and the application of machine learning/artificial intelligence to many aspects of PT. 156,157…”
Section: Technology Developmentsmentioning
confidence: 99%