An Adaptive Hybrid Control of Reduced Switch Multilevel Grid Connected Inverter for Weak Grid Applications

Abstract: Grid-connected inverters have a very significant role in the integration of renewable energy resources with utility grids. However, in recent studies, it is revealed that grid-connected inverters are vulnerable to instability when the nature of the grid changes from strong to weak, which produces uncertainty and performance degradation. An increase in grid impedance decreases stability margins, tremendously increases total harmonic distortion after a certain limit, and amplifies the voltage harmonics in the gr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 35 publications
0
2
0
Order By: Relevance
“…Parameter Complexity Amount of Total Harmonic Distortion [19] Unnecessary Low Medium [20] Unnecessary Low Medium [21] Necessary Medium Medium [22] Necessary Medium Low [23] Unnecessary Medium Medium [24] Necessary Complexity Low Proposed AFDC Unnecessary Low Low…”
Section: Control Strategymentioning
confidence: 99%
“…Parameter Complexity Amount of Total Harmonic Distortion [19] Unnecessary Low Medium [20] Unnecessary Low Medium [21] Necessary Medium Medium [22] Necessary Medium Low [23] Unnecessary Medium Medium [24] Necessary Complexity Low Proposed AFDC Unnecessary Low Low…”
Section: Control Strategymentioning
confidence: 99%
“…The enhanced voltage produced by the DC/DC converter needs to be converted into AC voltages. In the literature, researchers have explored various inverter topologies [32][33][34][35] and switching mechanisms [36][37][38] to facilitate this conversion process.…”
Section: Introductionmentioning
confidence: 99%
“…The stability margin of the three-phase, four-wire inverter, when connected to a weak electric grid with parallel compensating capacitors, is relatively low for positive, negative, and zero-sequence conditions. The interaction between the grid-tied inverter and the public power grid results in high-frequency oscillations in the system, posing a serious threat to the stable operation of the power system [10,11].…”
Section: Introductionmentioning