2020
DOI: 10.1109/jestpe.2019.2933140
|View full text |Cite
|
Sign up to set email alerts
|

An Adaptive Differentiation Frequency Based Advanced Reference Current Generator in Grid-Tied PV Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 32 publications
(17 citation statements)
references
References 39 publications
0
17
0
Order By: Relevance
“…The calculated (Ira, Irb, and Irc) and actual grid Iga, Igb, and Igc currents are given input to the PWM controller to evaluate the switching signals to the grid‐forming inverter for power quality enrichment by mitigating the harmonics in REGS applications. For the dc‐link voltage controller, the fuzzy gain tuning PID controller 11,37 is considered in the proposed controller.…”
Section: Proposed Control Schemementioning
confidence: 99%
See 1 more Smart Citation
“…The calculated (Ira, Irb, and Irc) and actual grid Iga, Igb, and Igc currents are given input to the PWM controller to evaluate the switching signals to the grid‐forming inverter for power quality enrichment by mitigating the harmonics in REGS applications. For the dc‐link voltage controller, the fuzzy gain tuning PID controller 11,37 is considered in the proposed controller.…”
Section: Proposed Control Schemementioning
confidence: 99%
“…In Reference 10, the authors have introduced a hybrid P&O with PSO‐based MPPT technique for the dc–dc converter to extract the maximum power from the PV system. In Reference 11, the authors have been employed a fuzzy gain scheduling proportional‐integral‐derivative (PID) for dc‐link voltage with an adaptive grid‐forming inverter control scheme for power quality and fundamental weight component (FWC) extraction.…”
Section: Introductionmentioning
confidence: 99%
“…These feedback signals, capacitor voltage, and reference signals set as inputs to the controller. Synchronous reference frame (SRF) control method has been used for control of output voltage and capacitor voltage using two control loops, and its modified version is discussed in the study by Babu et al The outer voltage loop is used to generate reference current Id* and Iq* for the inner current loop as shown in Figure B,C. The inner current loop generates the gate control signals to the HC‐MLI.…”
Section: Simulation and Experimantation Validationmentioning
confidence: 99%
“…The pulse patterns are obtained using a look‐up table depending on the values of m a . The outputs of the controller block are given to the digital output modules of DSP for generating the gate control signals (G s , G s1 , Gs 2 , Gs 3 , … and Gs n ) . The dc source ( V DC ) of the two primary H‐bridges is taken as 60 V whereas that for the capacitor voltage ( V CAP ) of the additional H‐bridge (H 3 ) shown in Figure is taken as 30 V. The capacitance is chosen as1000 μF.…”
Section: Simulation and Experimantation Validationmentioning
confidence: 99%
“…They have not fully explored the parametric uncertainties present in the system. In [22][23][24][25], the authors have proposed an adaptive current control regulator for grid-connected PV solar applications. They have explored the harmonic suppressions present in the grid PV system and proposed robust fuzzy logic-based active filter to prevent malfunctioning of devices.…”
Section: Introductionmentioning
confidence: 99%