An active catheter with integrated circuit for communication and control

Abstract: This paper describes an active catheter with flexible polyimide-based integrated CMOS interface circuits for communication and control (C&C IC) to be used for applications in biomedicine. The active catheter has a multilink structure and distributed micro Shape Memory Alloy (SMA) coils are utilized as actuators for multi-degree of freedom movement. The C&C ICs are incorporated within the links and require three common lead wires to address all the links and control the selected SMA actuators in the active cath… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2000
2000
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 8 publications
(3 reference statements)
0
13
0
Order By: Relevance
“…A similar configuration with active SMA-wires, making the servo-motors unnecessary, seems possible. A steerable miniature catheter was presented in [3]. This device was only 1.2 [mm] in diameter with a 0.3 [mm] diameter working channel and consisted of a sequence of segments.…”
Section: Applicationsmentioning
confidence: 99%
“…A similar configuration with active SMA-wires, making the servo-motors unnecessary, seems possible. A steerable miniature catheter was presented in [3]. This device was only 1.2 [mm] in diameter with a 0.3 [mm] diameter working channel and consisted of a sequence of segments.…”
Section: Applicationsmentioning
confidence: 99%
“…Its diameter is 8mm and only the head is controlled. Another has been proposed in (Park, K. & Esashi, M. 1999). This prototype is of diameter 1.7mm and is dedicated to interventions in ureter.…”
Section: Introductionmentioning
confidence: 99%
“…This will be achieved by using a polymer gel actuated prism. (Park & Esashi, 1999) As medical device, a flexible polymer sheath should protect the whole system. Each joint is provided with two antagonist electrically commanded SMA spring-like actuators allowing the control of the relative orientation of consecutive links.…”
Section: Introductionmentioning
confidence: 99%
“…Developments of new prototypes, aiming at improving the navigation of endoscopes in the inspected ducts, are in progress. A prototype developed in Japan (Park, K. & Esashi, M. 1999) is constituted of trays interconnected by SMA threads (Fig. 1).…”
Section: Introductionmentioning
confidence: 99%