1982
DOI: 10.1088/0022-3735/15/9/022
|View full text |Cite
|
Sign up to set email alerts
|

An accurate digital instrument for the measurement of circular polarisation of luminescence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
21
0

Year Published

1992
1992
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(24 citation statements)
references
References 16 publications
3
21
0
Order By: Relevance
“…It should be emphasized that plotting g lum ( t ) is merely a convenient way to represent the difference and trends in the decay curves of the two polarizations and does not bear an important physical significance on its own. As observed in Figure 3d, g lum ( t ) starts at ~−0.8, at t ≈ 0, in agreement with the value of the steady‐state g lum of the 595‐nm line of Eu(facam) 3 , −0.78 16 . A significant change is observed in g lum ( t ), decreasing in a roughly linear fashion with time toward zero with a time constant on the order of 1 ms, which is longer than the average emission lifetime.…”
Section: Resultssupporting
confidence: 85%
See 1 more Smart Citation
“…It should be emphasized that plotting g lum ( t ) is merely a convenient way to represent the difference and trends in the decay curves of the two polarizations and does not bear an important physical significance on its own. As observed in Figure 3d, g lum ( t ) starts at ~−0.8, at t ≈ 0, in agreement with the value of the steady‐state g lum of the 595‐nm line of Eu(facam) 3 , −0.78 16 . A significant change is observed in g lum ( t ), decreasing in a roughly linear fashion with time toward zero with a time constant on the order of 1 ms, which is longer than the average emission lifetime.…”
Section: Resultssupporting
confidence: 85%
“…As observed in Figure 3d, g lum (t) starts at $−0.8, at t ≈ 0, in agreement with the value of the steady-state g lum of the 595-nm line of Eu(facam) 3 , −0.78. 16 A significant change is observed in g lum (t), decreasing in a roughly linear fashion with time toward zero with a time constant on the order of 1 ms, which is longer than the average emission lifetime. Thus, the plot of g lum (t) might indicate that the heterogeneity of the emitting species is expressed mostly at the tail of the emission decay.…”
Section: Resultsmentioning
confidence: 93%
“…The signals correspond to the observed CPL and total luminescence intensities, respectively. The calibration factor for the system, F, was determined using a standard of the g em value ( g em =−0.78 at 595.2 nm) of tris(3‐trifluoroacetyl‐(+)‐camphorato)europium(III), [Eu((+)‐facam) 3 ], in dry DMSO . The slit width of the monochromator was set as narrow as possible in the measurement of the standard Eu III sample.…”
Section: Methodsmentioning
confidence: 99%
“…Tris europium trifluoromethylcamphorate (Eu(facam) 3 , facam = L 7 ; Scheme 4) in dimethylsulphoxide displays a g lum of |0.78| 41 and it is used as a standard for CPL instruments calibration, 42 even though this practice has been recently criticized and other systems have been proposed. 43 Recently, Eu(facam) 3 complexes with several ancillary ligands have been synthesized and their CPL measured in solution.…”
Section: Camphor-based Systemsmentioning
confidence: 99%