An Accelerated Distance Protection of Transmission Lines Emanating From MMC-HVdc Stations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 33 publications
0
3
0
Order By: Relevance
“…CT saturation can cause the measured differential current to (1) Frequency-Domain based scheme [7][8][9]14] The fault behaviors of MMC are considered. Thus, they can operate well in the presence of MMC-HVDC stations Inherent demerits of frequency-domain based scheme include the requirement of discrete Fourier transform, the negative effect of decaying DC component on accuracy of phasor estimation Some of them have no natural phase selection capability [7][8][9] Time-Domain based scheme [10][11][12][13]15] Discrete Fourier transform is removed. They exhibit good operating speed and low complexity Some of them are not applicable to MMC-HVDC stations.…”
Section: Analysis Of Differential Current Waveformsmentioning
confidence: 99%
See 1 more Smart Citation
“…CT saturation can cause the measured differential current to (1) Frequency-Domain based scheme [7][8][9]14] The fault behaviors of MMC are considered. Thus, they can operate well in the presence of MMC-HVDC stations Inherent demerits of frequency-domain based scheme include the requirement of discrete Fourier transform, the negative effect of decaying DC component on accuracy of phasor estimation Some of them have no natural phase selection capability [7][8][9] Time-Domain based scheme [10][11][12][13]15] Discrete Fourier transform is removed. They exhibit good operating speed and low complexity Some of them are not applicable to MMC-HVDC stations.…”
Section: Analysis Of Differential Current Waveformsmentioning
confidence: 99%
“…However, the proposed scheme cannot operate accurately under symmetrical faults. The authors in [8] propose a primary protection scheme based on improved distance protection and fiber-optic communication, which can operate correctly under all fault types. However, there are still some limitations, such as the inability to identify fault phases and slow operation in some cases.…”
Section: Introductionmentioning
confidence: 99%
“…Each logical judgment process can be regarded as a relay, although these relays are not real and are called virtual relays. Using virtual relays can help better simulate the protection system and provide a more accurate description of the relay protection system's behavior [8].…”
Section: Introductionmentioning
confidence: 99%