2005
DOI: 10.1158/1078-0432.ccr-04-1439
|View full text |Cite
|
Sign up to set email alerts
|

An 19F Magnetic Resonance–Based In Vivo Assay of Solid Tumor Methotrexate Resistance: Proof of Principle

Abstract: Purpose: Studies in oncology have implicated multiple molecular mechanisms as contributors to intrinsic and acquired tumor resistance to antifolate therapy. Here we show the utility of an 19 F-labeled methotrexate (FMTX) with 19 F magnetic resonance to differentiate between sensitive and resistant tumors in vivo and thus predict therapeutic response.Experimental Design: Human sarcoma xenografts in nude mice were used in this study. The sarcoma cell lines chosen for this study (HT-1080, HS-16, and M-805) are w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2006
2006
2012
2012

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 30 publications
0
3
0
Order By: Relevance
“…The coil was then tuned to 19 F, after which the PCE 19 F resonance frequency was determined with a pulse-acquire [11] sequence (1 shot). 19 F GRE imaging at the same exact anatomical level was then repeated (64×64 resolution, TR/TE = 4.3/1.8 ms, 1024 averages, 4.7 min/slice).…”
Section: Methodsmentioning
confidence: 99%
“…The coil was then tuned to 19 F, after which the PCE 19 F resonance frequency was determined with a pulse-acquire [11] sequence (1 shot). 19 F GRE imaging at the same exact anatomical level was then repeated (64×64 resolution, TR/TE = 4.3/1.8 ms, 1024 averages, 4.7 min/slice).…”
Section: Methodsmentioning
confidence: 99%
“…Non-triggered 1 H 1286128 TOF-GRE (TR/TE = 6.1/2.8 ms) and 64664 TOF-GRE (TR/TE = 4.7/2.0 ms) images with a high radiofrequency excititation angle (not quantifiable since it varies with distance from the surface coil) were acquired in the 3 principal directions (field of view 30630 cm 2 , slice thickness 2 or 3 mm, 32 averages, 25 s/slice and 10 s/slice, respectively) as well as 64664 ECG-triggered axial TOF-GRE images through the heart at the same location (4 averages, ,1 min/slice). The coil was then tuned to 19 F, after which the PCE 19 F resonance frequency was determined with a pulse-acquire [11] sequence (1 shot). 19 F GRE imaging at the same exact anatomical level was then repeated (64664 resolution, TR/TE = 4.3/1.8 ms, 1024 averages, 4.7 min/slice).…”
Section: Methodsmentioning
confidence: 99%
“…Spees et al [156] followed pharmacokinetics of fluorine-labeled methotrexate in sensitive and resistant tumor xenografts in mice and found an inverse correlation between surviving fraction and area under the curve. …”
Section: Other Anticancer Drugsmentioning
confidence: 99%