Amperometric Sarcosine Biosensors Based on Electrodeposited Conductive Films Contain Indole‐6‐carboxylic Acid

Abstract: Sarcosine level in serum is of important clinical significance in distinguishing prostate cancer. This work depicts an amperometric sarcosine biosensor with good anti‐interference performance by electro‐codepositing manganese phosphate, 3,4‐ethylenedioxythiophene (EDOT) and indole‐6‐carboxylic acid (IA) on the glass carbon electrode. The prepared sarcosine biosensor has a wide linear detection range (1–55 μM) with a low detection limit of 0.11 μM. This work provides an anti‐interference approach by controlling… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 45 publications
0
1
0
Order By: Relevance
“…Chitosan@Glassycarbon electrode, Nafion@Glassycarbon electrode and PEDOT‐IA/Pt/MnPO 4 /GlassycarbonElectrode each had residual current signals towards 100 μM amino acid that are 27.56 %, 19.74 %, and 6.91 %, accordingly, under the identical circumstances. for the mentioned findings demonstrate that PEDOT‐IA/Pt/MnPO 4 /Glassy Carbon Electrode has a significantly greater anti‐interference ability than nafion and chitosan [87] …”
Section: Carbon Quantum Dots and Graphene Quantum Dots As A Probe For...mentioning
confidence: 74%
See 1 more Smart Citation
“…Chitosan@Glassycarbon electrode, Nafion@Glassycarbon electrode and PEDOT‐IA/Pt/MnPO 4 /GlassycarbonElectrode each had residual current signals towards 100 μM amino acid that are 27.56 %, 19.74 %, and 6.91 %, accordingly, under the identical circumstances. for the mentioned findings demonstrate that PEDOT‐IA/Pt/MnPO 4 /Glassy Carbon Electrode has a significantly greater anti‐interference ability than nafion and chitosan [87] …”
Section: Carbon Quantum Dots and Graphene Quantum Dots As A Probe For...mentioning
confidence: 74%
“…for the mentioned findings demonstrate that PEDOT-IA/Pt/MnPO 4 /Glassy Carbon Electrode has a significantly greater anti-interference ability than nafion and chitosan. [87] Figure 6. Schematic presentation of sensing of sarcosine using A-IDA.…”
Section: Amperometric-based Sarcosine Sensormentioning
confidence: 99%
“…Characterisation of electrochemical properties of the modified electrodes.-From the catalytic principles of sarcosine biosensors, an excellent sarcosine biosensor has the following three requirements for its electrocatalytic material: high ability to conduct electrons, excellent catalytic response to H 2 O 2 , and a diffusioncontrolled kinetic process for its catalytic reaction. [32][33][34][35][36][37][38] Electrocatalysis experiments with H 2 O 2 were performed on the modified electrodes to initially determine whether they could be further modified as enzyme biosensors. The results are shown in Fig.…”
Section: Resultsmentioning
confidence: 99%