2008
DOI: 10.1016/j.msec.2006.12.003
|View full text |Cite
|
Sign up to set email alerts
|

Amperometric glucose biosensor based on in situ electropolymerized polyaniline/poly(acrylonitrile-co-acrylic acid) composite film

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
25
1

Year Published

2008
2008
2022
2022

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 61 publications
(28 citation statements)
references
References 24 publications
2
25
1
Order By: Relevance
“…Zhou et al [22]investigated a sensitive and selective amperometric glucose biosensor based on platinum microparticles dispersed in nanofibrous PAN. PAN hybrid materials, which combine PAN with other kinds of nanomaterials, especially metal nanoparticles [23], play an important role in biosensors and electrochemical sensors [24,25]. During recent years, bimetallic alloy nanoparticles, such as Au-Pt, Pt-Fe, Pt-Ni, Pt-Co, and Pt-Cr [26 -28] etc., have attracted considerable interest in the field of catalysis and sensors because they often exhibit better catalytic properties than do their monometallic counterparts.…”
Section: Introductionmentioning
confidence: 99%
“…Zhou et al [22]investigated a sensitive and selective amperometric glucose biosensor based on platinum microparticles dispersed in nanofibrous PAN. PAN hybrid materials, which combine PAN with other kinds of nanomaterials, especially metal nanoparticles [23], play an important role in biosensors and electrochemical sensors [24,25]. During recent years, bimetallic alloy nanoparticles, such as Au-Pt, Pt-Fe, Pt-Ni, Pt-Co, and Pt-Cr [26 -28] etc., have attracted considerable interest in the field of catalysis and sensors because they often exhibit better catalytic properties than do their monometallic counterparts.…”
Section: Introductionmentioning
confidence: 99%
“…30 Over 0.6 V, the response was controlled normally by diffusion of the substrate and the product. 37 In this case, the influence of H + yielded after rapid electro-oxidation is dominant. The yielded H + not diffused into bulk solution may accumulate in the biomembrane due to an excess negatively charge of the hybrid system, resulting in a shift of the local pH within the hybrid biocoating and hence to a decrease in the enzymatic rate.…”
Section: Optimization Of Detection Test Variablesmentioning
confidence: 99%
“…Polymer films, and particularly those based on substituted aromatic compounds, such as aniline, present interesting characteristics, namely high conductivity, stability, durability, and reproducibility associated with low costs (Bhadra et al, 2009;Casella & Guascito, 1997;Gornall et al, 2009;Grennan et al, 2006;Huang et al, 2002Huang et al, , 2003Šeděnková et al, 2008;Shan et al, 2008;Trashin et al, 2009;Waltman & Bargon, 1986;Yin et al, 2006). Their main drawback is related to their preparation which involves handling of the respective monomers which are potentially hazardous materials.…”
Section: Introductionmentioning
confidence: 99%