2008
DOI: 10.2116/analsci.24.487
|View full text |Cite
|
Sign up to set email alerts
|

Amperometric Biosensor for Hydrogen Peroxide Based on Direct Electrocatalysis by Hemoglobin Immobilized on Gold Nanoparticles/ 1,6-Diaminohexane Modified Glassy Carbon Electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…Hemoglobin (Hb) has been extensively studied as a redox protein for direct electron transfer to AuNP-modified electrodes. Hb has very slow electron transfer rate to bulk electrodes, however, AuNPs can greatly enhance the electron transfer between Hb and electrodes with or without redox mediator. Yuan has used this system for amperometric sensing of H 2 O 2 using Hb immobilized on multiwall carbon nanotubes (MWCNT)/AuNPs and onto AuNPs/MWCNT/chitosan composite matrices on GCE surface. Amperometric nitrite sensors have used Hb immobilized on AuNP-modified screen printed electrode and onto one-dimensional AuNP assemblies .…”
Section: Electrical and Electrochemical Sensingmentioning
confidence: 99%
“…Hemoglobin (Hb) has been extensively studied as a redox protein for direct electron transfer to AuNP-modified electrodes. Hb has very slow electron transfer rate to bulk electrodes, however, AuNPs can greatly enhance the electron transfer between Hb and electrodes with or without redox mediator. Yuan has used this system for amperometric sensing of H 2 O 2 using Hb immobilized on multiwall carbon nanotubes (MWCNT)/AuNPs and onto AuNPs/MWCNT/chitosan composite matrices on GCE surface. Amperometric nitrite sensors have used Hb immobilized on AuNP-modified screen printed electrode and onto one-dimensional AuNP assemblies .…”
Section: Electrical and Electrochemical Sensingmentioning
confidence: 99%
“…In order to ensure sensitivity and stability of an immunosensor, the antibodies must be suitably immobilized on the transducer and maintain their biological activity after the immobilization process [27]. Procedures that satisfy these requirements include the use of self-assembled monolayers on gold [28,29] and carbon surfaces [23,30], functionalized nanoparticles [31,32], and polymeric films [33,34]. It is also possible to perform the immobilization of a biomolecule by means of groups generated directly on the glassy carbon electrode surface, instead of using additional reagents to fulfil this role in the assay.…”
Section: Introductionmentioning
confidence: 99%
“…Many techniques have been developed to quantify nitric oxide levels in biological settings. Two common approaches are the use of small-molecule labeling dyes and specially coated electrodes. Dyes are usually delivered intracellularly or in the interstitia where they bind reactive species and indicate species concentration through either fluorescence or chemiluminescence. However, dyes such as the widely used 4,5-diaminofluorescein respond to all species that nitrosate the substrate, including many NO decomposition products.…”
Section: Swcnt Uptake and Colocalization In Melanoma Cellsmentioning
confidence: 99%