2013
DOI: 10.1016/j.aca.2013.08.018
|View full text |Cite
|
Sign up to set email alerts
|

Amorphous carbon nitride as an alternative electrode material in electroanalysis: Simultaneous determination of dopamine and ascorbic acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
23
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 45 publications
(25 citation statements)
references
References 51 publications
2
23
0
Order By: Relevance
“…485.1 mV for EPPG and 500.2 mV GCE), after was carried out successive additions of AP into a 0.1 mol L −1 phosphate buffer solution, pH 7.0. , however it is most remarkable the VXC72RCB-CTS/GCE exhibits an improvement over that of EPPG in terms of the observed sensitivity (slope of the calibration plot); usually EPPG shows the best sensitivity among different carbonaceous materials as can found in the literature [6,52,53]. The linear equations for the electroanalytical response using VXC72RCB-CTS/GCE are as follows: j (µAcm DA concentrations have been associated with neurological disorders; thus, the determination of the DA concentration can be very important in diagnostic applications [7,54]. As shown in Fig.…”
Section: Electroanalytical Applicationsmentioning
confidence: 94%
“…485.1 mV for EPPG and 500.2 mV GCE), after was carried out successive additions of AP into a 0.1 mol L −1 phosphate buffer solution, pH 7.0. , however it is most remarkable the VXC72RCB-CTS/GCE exhibits an improvement over that of EPPG in terms of the observed sensitivity (slope of the calibration plot); usually EPPG shows the best sensitivity among different carbonaceous materials as can found in the literature [6,52,53]. The linear equations for the electroanalytical response using VXC72RCB-CTS/GCE are as follows: j (µAcm DA concentrations have been associated with neurological disorders; thus, the determination of the DA concentration can be very important in diagnostic applications [7,54]. As shown in Fig.…”
Section: Electroanalytical Applicationsmentioning
confidence: 94%
“…25 Some groups have also reported electrochemical responses of nitrogen containing carbon film electrodes. [26][27][28][29][30] However, very few reports studied the relationship between carbon film structures, particularly about chemical bonds and electrocatalytic properties. 9,19 In this work, we studied N-UBM nanocarbon film electrodes with relatively low nitrogen concentration in terms of structural dependence of ORR.…”
Section: Electrocatalytic Reduction Of Oxygenmentioning
confidence: 99%
“…48 DA and AA coexist in the brain intercellular fluid in different concentrations. Recently, much efforts have been devoted to the development of simultaneous determination of DA and AA by electrochemical techniques, 49 as they are easily electrochemically oxidized. However, the oxidation potential of DA commonly appears similar to that of AA, 50 therefore, various materials have been selected and modified on the surface of the electrode in order to simultaneously detect DA and AA, such as metal nanoparticles, 51 graphene, 52 carbon nanotubes, 53 polymers, 54 or their composite materials.…”
Section: Morphology and Characterization Of Pils/ppyntsmentioning
confidence: 99%